16 | 18
Appendix
Datasheet
Number of measuring channels: 1 (Strain gauge full bridge > 300 Ω)
Supply voltage:
12E - 10 … 18 VDC
24E - 18 … 30 VDC
Electronics protected against voltage reversal
Isolating proof voltage input to output: 200 V Higher isolated proof voltage on request
Power consumption: max. 3 W
Strain gauge excitation supply: ±2,5 VDC ± 1% / ±5 VDC ± 1%
Analogue output
0 … 10 V / ±10 V
4 … 20 mA
max. 1 mA (short-period short-circuit proof)
max. 500 Ω
Limit frequency (-3 dB): 1 kHz (10 Hz with low pass filter)
optional up to 30 kHz
Input resistance: >3 MΩ
Max. input sensitivity: 100 mV/V at ±5 VDC excitation supply
Non-linearity: ±0.05 % FSO
Electrical connection: Pluggable Screw clamps
Housing: Plastic enclosure for top hat rail mounting
(
IP20)
Dimension (W x H x D): 23 x 99 x 115 mm
Weight: approx. 150 g
Temperature, storage: -20 °C … +60 °C
Temperature, operating: 0 °C … +50 °C
Order designation
Single channel strain gauge
amplifier in plastic housing for DIN
…-12E-…
Supply voltage: 10 … 18 VDC
Supply voltage: 18 … 30 VDC
…-010-…
Analogue output: 0 … 10 V
…-B10-…
Analogue output: ± 10 V
Analogue output: 0 … 10 V and 4 … 20 mA
… -GFxxx
frequency limit up to 30 kHz
…no declaration
standard version 1 kHz