EasyManua.ls Logo

Alto-Shaam AR-7

Alto-Shaam AR-7
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18. #852 AR-7E ROTISSERIE INSTALLATION/OPERATION/SERVICE MANUAL
SECTION 3 ROTISSERIE SERVICE SECTION SECTION 3
THIS SECTION IS PROVIDED FOR THE ASSISTANCE OF QUALIFIED SERVICE TECHNICIANS ONLY
AND IS NOT INTENDED FOR USE BY UNTRAINED OR UNAUTHORIZED SERVICE PERSONNEL
.
DISCONNECT ELECTRICAL POWER TO THE ROTISSERIE BEFORE SERVICING.
LOCK-OUT OR POST BREAKER PANEL UNTIL SERVICE WORK HAS BEEN COMPLETED.
TROUBLESHOOTING
ERROR POSSIBLE CAUSE
CODE DESCRIPTION/RESULTS SERVICE REQUIRED
E-10 Air Sensor Fault (shorted) Air sensor defective?
E-11 Air Sensor Fault (open) AIR SENSOR TEST
Inoperative Oven Test air sensor by placing sensor in ice water bath. Use an ohm
meter set on the ohm scale. The reading should be 100 ohms
resistance. The sensor must be replaced if the reading is more
than 2 ohms higher or lower.
E-20 Product Probe Fault (shorted) Probe defective?
E-21 Product Probe Fault (open) PROBE SENSOR TEST
Oven will cook in TIME mode only Test food probe by placing in ice water bath. Use an ohm meter
set on the ohm scale. The reading should be 100 ohms
resistance.
E-30 Under Temperature Door gasket need replacement?
Oven will shut down Preheating procedure skipped?
Oven overloaded or frozen product used?
Defective air sensor or probe?
E-31 Over Temperature Defective air sensor?
Oven will shut down AIR SENSOR TEST
Test air sensor by placing sensor in ice water bath. Use an ohm
meter set on the ohm scale. The reading should be 100 ohms
resistance. The sensor must be replaced if the reading is more
than 2 ohms higher or lower.
E-60 Real Time Clock Error Control must be replaced.
Inoperative Oven
E-70 Configuration Connector Error Check control connections for loose wires.
Inoperative Oven If none, control must be replaced.
E-78 Voltage Low If 208-240 VAC voltage is below 190 VAC. Correct.
E-79 Voltage High If 208-240 VAC, voltage is over 250 VAC. Correct.
Inoperative Oven
E-80 EEPROM - Function Data Error
E-82 EEPROM - Calibration Data Error
E-84 EEPROM - Unit ID Error
E-86 EEPROM - Preset Data Error
Inoperative Oven Replace control.