CTP Combitherm
76
MN-35948
Rev 16
10/18
Combitherm® CT PROformance™ Series Operator’s Manual
Error
Code
Error Call Out in Display Description of Error Possible Cause(s)
E06 Lower VFD Comm Failure When VFD does not respond to a
query on the CAN interface.
— Loss of power to VFD.
— VFD malfunction.
— CAN cable disconnected.
— CAN address not correct on VFD.
E07 Error Received from VFD When VFD is flashing the green
light
Refer to VFD error code list and match to number of blinks
on the green LED of VFD.
E08 Error Received from Lower VFD When VFD is flashing the green
light
Refer to VFD error code list and match to number of blinks
on the green LED of VFD.
E11 Convection Temperature High In Combination program, cavity
temperature N6 is measuring
in excess of 572ºF (300ºC) for a
minimum of 25 seconds
In Convection program, cavity
temperature N6 is measuring
in excess of 572ºF (300ºC) for a
minimum of 25 seconds
— Check wiring to all components mentioned below.
Steam element contactor locked/on.
— N6 oven cavity temperature probe is defective.
N6 oven cavity temperature probe wires connected
backwards
— Relay board, high voltage, defective.
E13 Boiler Temperature High Boiler temperature is more than
248ºF (120ºC) for more than 25
seconds, detected by B4 Probe
Calcium build up in boiler
Check wiring to all components mentioned below.
— Steam element contactor locked/on.
— B4 boiler temperature probe is defective.
B4 probe wires connected backwards
Water level probe has calcium build up.
E15 Condensor Temperature High Condensor water temperature is
more than 212ºF (100ºC) for more
than 180 seconds, detected by B3
probe
Water supply is shut o .
Check wiring to all components mentioned below.
B3 condensor temperature probe is defective.
B3 condensor probe wires connected backwards
— Single water solenoid valve defective (Y2).
Relay board, high voltage, defective.
E20 B11 Core Temperature Probe
Single Point Fault
Single point core temperature
probe defective or disconnected
Clean probe receptacle pins with sand paper.
B11 Single Point Core Temperature probe with quick
connect defective.
B11 Single Point Core Temperature probe wires with quick
connect disconnected.
B11 Single Point Core Temperature probe receptacle
defective.
B11 Single Point Core Temperature probe receptacle wires
disconnected.
E21 N6 Cavity Probe Fault Cavity temperature probe
defective or disconnected
N6 oven cavity temperature probe defective.
— N6 oven cavity temperature probe wires.
E22 B10 Core Temperature Probe
Multi-point Fault
Multipoint core temperature
probe defective or disconnected
— B10 multipoint core temperature probe defective.
— B10 multipoint core temperature probe wires disconnected.
E23 B4 Boiler Probe Fault Boiler temperature probe
defective or disconnected
— B4 boiler temperature probe defective.
— B4 probe wires connected backwards.
E24 B5 Bypass Probe Fault Bypass steam temperature probe
defective or disconnected
— B5 bypass steam temperature probe defective.
B5 bypass steam temperature probe wires connected
backwards.
E25 B3 Condensor Probe Fault Condensor water temperature
probe defective or disconnected.
— B3 condensor temperature probe defective.
B3 condensor probe wires connected backwards.
E26 B10 - Point 1 - Core Temperature
Probe Multipoint Fault
Multipoint core temperature
probe defective or disconnected.
B10 Multipoint Core Temperature probe defective.
B10 Multipoint Core Temperature probe wires disconnected.
E27 B10 - Point 2 - Core Temperature
Probe Multipoint Fault
Multipoint core temperature
probe defective or disconnected.
B10 Multipoint Core Temperature probe defective.
B10 Multipoint Core Temperature probe wires disconnected.
Error Codes
   

Table of Contents

Other manuals for Alto-Shaam COMBITHERM CTP6-10G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alto-Shaam COMBITHERM CTP6-10G and is the answer not in the manual?

Alto-Shaam COMBITHERM CTP6-10G Specifications

General IconGeneral
BrandAlto-Shaam
ModelCOMBITHERM CTP6-10G
CategoryConvection Oven
LanguageEnglish

Related product manuals