Error
Code
Error Call Out in Display Description of Error Possible Cause(s)
E200 The SD card has been detected
to be larger than 2GB in size.
The SD card inserted is larger
than 2GB in size.
SD card is larger than 2GB in size. Contact service to order
replacement SD card.
E210 VFD Under Voltage VFD has detected an under-
voltage situation.
— Possible VFD failure.
E211 VFD Over Voltage VFD has detected an over-voltage
situation.
— Possible VFD failure.
E212 VFD Overheating VFD has detected an overheat
situation.
— Unit has experienced an over heat condition.
— Defective high limit switch.
— Defective cooling fans.
— Possible VFD failure.
E213 Motor Over Current Motor over current detected. — Blocked fan wheel.
— Possible VFD failure.
E214 VFD Current Peak VFD current peak detected. — Possible VFD failure.
E215 VFD EEPROM Error VFD EEPROM error detected. — Possible VFD failure.
E216 VFD Over Current VFD over current detected. — Possible VFD failure.
E217 VFD Short Circuit VFD Short Circuit detected. — Possible VFD failure.
E218 VFD Voltage Error VFD voltage does not correspond
to jumper settings.
— VFD voltage jumper is not correct.
— Possible VFD failure.
E220 Lower VFD Under Voltage Lower VFD has detected an
under-voltage situation.
— Possible Lower VFD failure.
E221 Lower VFD Over Voltage Lower VFD has detected an over-
voltage situation.
— Possible Lower VFD failure.
E222 Lower VFD Overheating Lower VFD has detected an
overheat situation.
— Unit has experienced an over heat condition.
— Defective high limit switch.
— Defective cooling fans.
— Possible Lower VFD failure.
E223 Lower Motor Over Current Lower Motor over current
detected.
— Possible Lower VFD failure.
E224 Lower VFD Current Peak Lower VFD current peak
detected.
— Possible Lower VFD failure.
E225 Lower VFD EEPROM Error Lower VFD EEPROM Error
detected.
— Possible Lower VFD failure.
E226 Lower VFD Over Current Lower VFD over current detected. — Possible Lower VFD failure.
E227 Lower VFD Short Circuit Lower VFD short circuit detected. — Possible Lower VFD failure.
E228 Lower VFD Voltage Error Lower VFD voltage does not
correspond to jumper settings.
— Lower VFD voltage jumper is not correct.
— Possible Lower VFD failure.
E289 Unknown Error from VFD VFD has provided an unknown
error.
— Possible VFD failure.
E290 Unknown Error from Lower
VFD
Lower VFD has provided an
unknown error.
— Possible Lower VFD failure.
Error Codes

Table of Contents

Other manuals for Alto-Shaam COMBITHERM CTP6-10G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alto-Shaam COMBITHERM CTP6-10G and is the answer not in the manual?

Alto-Shaam COMBITHERM CTP6-10G Specifications

General IconGeneral
BrandAlto-Shaam
ModelCOMBITHERM CTP6-10G
CategoryConvection Oven
LanguageEnglish

Related product manuals