EasyManua.ls Logo

Alto-Shaam Converge CMC-H2H

Alto-Shaam Converge CMC-H2H
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TROUBLESHOOTING
Co nv erg e® Se rvice Ma nual MN-47 241 Rev 1 6 /22
81
Is the steam relay closing and completing the circuit
to the solenoid valve?
No
Check voltage to the steam relay.
Make sure correct line voltage is
supplied to the COM and NO
connections on the relay and follow
the wiring back TB 16 and 22 to
make any corrections. If all voltages
are OK, then replace the steam
relay.
Yes
Is water flowing into the cavity?
No
Inspect water lines and hoses to the
cavity for any restrictions or plugs.
Correct any issue and retest. If lines
are free and clear and valve is not
opening when power is supplied,
replace the water solenoid valve.
Yes
The oven is performing as intended.

Table of Contents

Other manuals for Alto-Shaam Converge CMC-H2H

Related product manuals