SCHEMATICS
Co nv erg e® Se rvice Ma nual MN-47 241 Rev 1 6 /22
99
SCHEME
REVISION
/
3
77777
5
11
12
11
10
9
8
7
6
5
4
3
2
1
STEAM CONTROL
TB-34
TB-32
1017
2017
CB X4-4
CB X4-1
08-9
08-12
HAND SHOWER RLY A2
HAND SHOWER RLY A1
06-8
FROM PS
04-6
NO
COM
A2 A1
NO
COM
A2 A1
TB-22
A2 A1
A2 A1
TB-16
SV RLY
Y1
1
2
1
2
TB-22
2083
2085
2084
2086
1086
801
1087
804
800
803
802
805
LWS RLY
1
2
NO
COM
A2 A1
NO
COM
A2 A1
TB-22
TB-22
2110
2097
2111
2098
08-12
08-12
EL 1
EL 2
1
2
1
2
1097
1098
810
811
812
813
LOW STEAM
STEAM RELAYS VALVES
647
648
FROM CB X2-9
FROM CB X2-10
FROM CB X2-7
FROM CB X2-8
FROM CB X1-5
FROM CB X1-3
FROM CB X1-6
FROM CB X1-4
C1
D1
D4
C4
B1
D2
B2
D1
04-6
A1
A1
A3
A3
06-7
08-10
08-12
08-12
08-12
08-12
08-12
RLY = RELAY
LEGEND
EL = ELEMENT
Y1 = STEAM VALVE
CB = CONTROL BOARD
SV = STEAM VALVE
LWS = STEAM RELIEVE VALVES

Table of Contents