TROUBLESHOOTING
Vector H Seri es Serv ic e M anua l MN- 4654 4 Re v 01 1 1/19
60
How to Test the Convection Fan Motors
Before you begin The oven must be connected to electric power.
Procedure
To test the convection fan motors, do the following.
Step Action
1. Touch the menu icon a. The user menu screen displays.
2. Touch the service icon b. The enter pass code screen displays.
3. Enter the pass code 6702 c.
Touch the check mark d. The general device screen displays.
Continued on next page
NOTICE
Do not turn on the heaters during this test. Damage to the
oven may occur.
VMC-TS-006259
a
VMC-TS-008129
b
VMC-TS-008131
c
d