TROUBLESHOOTING
Ve ct or H Se ries S ervice Ma nual MN -4 654 4 Rev 0 1 11/19
71
Continued from previous page
7. Touch the target temperature setting h. The select temperature screen
displays.
Enter chamber
temperature
8. Enter a temperature higher than the current chamber temperature i.
Touch the check mark. The target temperature is displayed.
Repeat for all chambers.
Set all chambers to the same temperature.
Insert the
thermocouple
9. Insert the thermocouple from the multimeter into the heated oven. Allow the
multimeter to stabilize.
Compare the reading from the multimeter’s thermocouple with the
temperature sensor reading displayed on the screen.
Continued on next page
VMC-TS-008180
h
VMC-TS-008182
h
i
VMC-TS-008198
450