1. Set up an account in the AlulaConnect portal.
2. Add the MASTER CODE to the primary account user before connecting the BAT-Connect. This is
required for the BAT-Connect to be able to properly congure the system settings.
3. Disarm the system (all partitions).
4. Enter panel programming mode using the installer code and program the following:
5. Exit programming mode and power down the DSC system.
6. Connect the DSC system and the BAT-Connect as shown in the wiring diagram on the next page.
7. Power up the DSC system.
The DSC control panel will begin automatic conguration. Panel keypads will be
unavailable during this time.
8. Verify proper operation and reporting of all event codes using your control panel’s installation
manual.
Note: During normal operation, BAT-Connect will occasionally use the panel bus for some system
tests. Typically, this lasts for 5-6 seconds. During this time, panel keypads will be unavailable.
Note: DSC Power Series panels may use different programming locations or the option
may not be available. Always refer to the installation manual of the specic panel for
programming locations and options.
Enable Communicator ([380]:[1])
Enter a Telephone Number ([301])
Enter Account Number ([310])
Verify 1st Telephone Number is enabled in Call Direction Options ([351]-[376])
Verify T-Link is Disabled ([382]:[5])
Verify Master Code Not Changeable is Disabled ([015]:[6])
Verify Access Code Required for *1, *2, *3 menus is disabled ([022]:[1])
Verify that keypad lockout is either zero (disabled) or higher than 6 ([012])
If you have removed any bus devices, perform a Module Supervision Reset ([902])
Set Communicator Format to Contact ID ([350])
Verify the panel is properly set up for Contact ID event reporting
To enable reporting of the Period Test Transmission, program the “Periodic Test
Transmission” ([348]:[4]) and the “Periodic Test Transmission with Trouble” ([348]:[3])
reporting codes to “02”(optional)