EasyManua.ls Logo

Alva GH301 - Specifications

Default Icon
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Q: I just took my heater from storage, but there seems
to be a blue ame rolling on the panels.
Is my heater faulty?
A: It is normal for dust to settle on the panel. When this
happens, the heater will not burn properly at rst, giving
the appearance of a blue ame running on the panel.
This might happen when you rst buy the unit after
you have stored it.There is nothing wrong with the
heater. Simply burn the dust off the panels by letting
the heater run on HI for between 5 and 15 minutes.
The panels should eventually settle and burn red.
Q: What do I do if I have an over-lled cylinder?
A: The best method to determine if your cylinder is over-
lled is to weigh it.Subtract the ‘tare’ mass from the
cylinder weight – this gives you the weight of your gas.
If this gas weight exceeds your cylinder design weight
(3kg) then return the cylinder to your gas
supplier.
SPECIFICATIONS
Model ALVA GH301
Type of Gas LPG
Operating pressure 2.8kPa
Injector size 0.95
Gas Consumption 165gr/hr
Heat output 4.2kW
This heater has been tested and is LPGSASA approved under
specications SANS 1539 (appliance), SANS 1237 (regulator)
and SANS 1156 (hose).
9

Related product manuals