6. Description of Display Screens
6-15
(f) DELAY TIME
Sets Delay Time, the time period from Weld Stop to the time when a final
displacement is measured (only for Sensor equipped). The setting range is
from 0 to the time period of HOLD TIME (See (3)
(b)).
(g) WORK DETECT
Input the upper limit (HI) / lower limit (LOW) value at the time of detecting
workpiece (only for Sensor equipped).
No detection of workpiece is done in the case that “0” is set to both the upper
limit and lower limit.
For the detection of workpiece, the position of Sensor where the workpiece is
set between electrodes is taken as the base point. The larger displacement
without workpiece than the displacement with workpiece is detected to judge
whether or not the workpiece is set.
(h) MONITOR
Displays the displacement at the time of detecting workpiece, the time of the
end of squeeze time (only for Sensor equipped).
Note) IPB-5000B holds the monitored value of all schedules (only the latest one
for waveform) while the power is on. When the power is turned off, all
values are cleared.