SS-AMVM96 www.amana-hac.com 3
2 www.amana-hac.com SS-AMVM96
P
roduCt
s
PeCiFiCAtions
P
roduCt
s
PeCiFiCAtions
sPeCiFiCAtions
AMVM96
0603BX
AMVM96
0805CX
AMVM96
1005DX
AMVM96
1155DX
ACVM96
0604CX
ACVM96
0805DX
High Fire Input (BTU/h)¹ 60,000 80,000 100,000 115,000 60,000 80,000
High Fire Output (BTU/h)¹ 57,600 76,800 96,000 109,250 57,600 76,800
Low-Fire Steady-State Input¹ 30,000 40,000 50,000 57,500 30,000 40,000
Low-Fire Steady-State Output¹ 28,800 38,400 48,000 54,625 28,800 38,400
AFUE² 96 96 96 95 96 96
Available AC @ 0.5” ESP 1.5-3.0 2.0-5.0 2.0-5.0 2.0-5.0 1.5-4.0 2.0-5.0
Temperature Rise Range (° F) 20-50 35-65 35-65 35-65 20-50 20-50
Size (D x W) 10" X 8" 11" X 10" 11" X 10" 11" X 10" 10"X 10" 11" X 10"
Horsepower @ 1050 RPM 3/4 1 1 1 3/4 1
Speed Variable Variable Variable
Vent Diameter³ 2" 3" 3" 3" 2" 2"
No. of Burners 3 4 5 5 3 4
Disposable Filter (in
2
) 576 960 960 972 641 854
6.0 14.2 14.2 14.2 6.0 14.2
15.0 15.0 15.0 15.0 15.0 15.0
135 145 170 170 139 165
¹ Natural Gas BTU/h
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.