SS-AMVM96 www.amana-hac.com 7
6 www.amana-hac.com SS-AMVM96
P
roduCt
s
PeCiFiCAtions
P
roduCt
s
PeCiFiCAtions
AMVM96 AirFlow dAtA — Cooling sPeeds
AMVM960603BX AVMV960805CX
   
  CFM*   CFM*   CFM*   CFM*
A
Minus(-) 567
A
Minus(-) 351
A
Minus(-) 747
A
Minus(-) 486
Normal 630 Normal 390 Normal 830 Normal 540
 693  429  913  594
B
Minus(-) 720
B
Minus(-) 495
B
Minus(-) 981
B
Minus(-) 675
Normal 800 Normal 550 Normal 1090 Normal 750
 880  605  1199  825
C
Minus(-) 900
C
Minus(-) 612
C
Minus(-) 1314
C
Minus(-) 882
Normal 1000 Normal 680 Normal 1460 Normal 980
 1100  748  1606  1078
D
Minus(-) 1089
D
Minus(-) 720
D
Minus(-) 1620
D
Minus(-) 1089
Normal 1210 Normal 800 Normal 1800 Normal 1210
 1331  880  1980  1331
* @ .1" - .8" w.c. ESP * @ .1" - .8" w.c. ESP
AMVM961005DX AMVM961155DX
   
  CFM*   CFM*   CFM*   CFM*
A
Minus(-) 711
A
Minus(-) 459
A
Minus(-) 711
A
Minus(-) 459
Normal 790 Normal 510 Normal 790 Normal 510
 869  561  869  561
B
Minus(-) 990
B
Minus(-) 639
B
Minus(-) 990
B
Minus(-) 639
Normal 1100 Normal 710 Normal 1100 Normal 710
 1210  781  1210  781
C
Minus(-) 1269
C
Minus(-) 819
C
Minus(-) 1269
C
Minus(-) 819
Normal 1410 Normal 910 Normal 1410 Normal 910
 1551  1001  1551  1001
D
Minus(-) 1647
D
Minus(-) 1044
D
Minus(-) 1647
D
Minus(-) 1044
Normal 1830 Normal 1160 Normal 1830 Normal 1160
 2013  1276  2013  1276
* @ .1" - .8" w.c. ESP

 All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
 For most jobs, about 400 CFM per ton when cooling is desirable.
 