SS-AMVM96 www.amana-hac.com 9
8 www.amana-hac.com SS-AMVM96
P
roduCt
s
PeCiFiCAtions
P
roduCt
s
PeCiFiCAtions
ACVM96 AirFlow dAtA — Cooling sPeeds
ACVM960604CX
A
Minus(-) 594
A
Minus(-) 333
Normal 660 Normal 370
726 407
B
Minus(-) 774
B
Minus(-) 486
Normal 860 Normal 540
946 594
C
Minus(-) 1035
C
Minus(-) 711
Normal 1150 Normal 790
1265 869
D
Minus(-) 1323
D
Minus(-) 882
Normal 1470 Normal 980
1617 1078
* @ .1" - .8" w.c. ESP
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
For most jobs, about 400 CFM per ton when cooling is desirable.
and .8” w.c. is tabulated for cooling purposes only.
ACVM960805DX
A
Minus(-) 810
A
Minus(-) 477
Normal 900 Normal 530
990 583
B
Minus(-) 990
B
Minus(-) 657
Normal 1100 Normal 730
1210 803
C
Minus(-) 1287
C
Minus(-) 837
Normal 1430 Normal 930
1573 1023
D
Minus(-) 1692
D
Minus(-) 1098
Normal 1880 Normal 1220
2068 1342
* @ .1" - .8" w.c. ESP
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
For most jobs, about 400 CFM per ton when cooling is desirable.
and .8” w.c. is tabulated for cooling purposes only.