Manual Operation of Magnetrons #1 & #2
Screen This screen will allow operation of
Magnetron #1 and #2 together and show the
number of amps being drawn.
NEXT TEST: Press this pad to go to the
next Service Mode Test
PREV TEST: Press this pad to go to the
previous Service Mode Test
TURN ON: This pad will toggle between
turning the magnetrons on and off.
CANCEL: Press this pad to return to the
Main Menu
RANGE: Under normal operation, each
mag’s amp draw should be 5 – 12 amps.
Manual Operation of Magnetron #1
Screen This screen will allow operation of
Magnetron #1 and show the number of
amps being drawn.
NEXT TEST: Press this pad to go to the
next Service Mode Test
PREV TEST: Press this pad to go to the
previous Service Mode Test
TURN ON: This pad will toggle between
turning the magnetron on and off.
CANCEL: Press this pad to return to the
Main Menu
RANGE: Under normal operation, the amp
draw should be 5 – 12 amps.