Loading...
Convection Fan – High Speed
Screen This screen will allow operation of the
convection fan at a high speed and show the
number of amps being drawn.
NEXT TEST: Press this pad to go to the
next Service Mode Test
PREV TEST: Press this pad to go to the
previous Service Mode Test
TURN ON: This pad will toggle between
turning the convection fan on and off at a
high speed.
CANCEL: Press this pad to return to the
Main Menu
RANGE: Under normal operation, the amp
draw should be 0.6 – 2.6 amps.
Cooling Fan
Screen This screen will allow operation of the
cooling fan show the number of amps being
drawn.
NEXT TEST: Press this pad to go to the
next Service Mode Test
PREV TEST: Press this pad to go to the
previous Service Mode Test
TURN ON: This pad will toggle between
turning the cooling fan on and off.
CANCEL: Press this pad to return to the
Main Menu
RANGE: Under normal operation, the amp
draw should be 0.9 – 2.5 amps.
8
9
(It may not read amps)
(It may not read amps)