Radiant Heater
Screen This screen will allow operation of the
radiant heater and show the number of
amps being drawn.
NEXT TEST: Press this pad to go to the
next Service Mode Test
PREV TEST: Press this pad to go to the
previous Service Mode Test
TURN ON: This pad will toggle between
turning the heater on and off.
CANCEL: Press this pad to return to the
Main Menu
RANGE: Under normal operation, the amp
draw should be 10 – 16 amps.
Convection Fan – Low Speed
Screen This screen will allow operation of the
convection fan at a low speed and show the
number of amps being drawn.
NEXT TEST: Press this pad to go to the
next Service Mode Test
PREV TEST: Press this pad to go to the
previous Service Mode Test
TURN ON: This pad will toggle between
turning the convection fan on and off at a
low speed.
CANCEL: Press this pad to return to the
Main Menu
RANGE: Under normal operation, the amp
draw is too low to read.