PRODUCT IDENTIFICATION
8
Heat Pumps and Coolers
HEAT PUMPS
COOLERS
Model # Manufacturing # Description
PHB**C02D P1214402C-P1214404C
P
ackage Heat Pump (B) 11 Seer heat pump units. New chassis design with smaller
footprint.
PHB**C02E P1204501C-P1214404C
P
ackage
H
eat Pump (
B
) 11 Seer heat pump units. New chassis design with smaller
footprint. Improved heating capacity
PHB**C02E P1220101C-P1220106C
P
ackage Heat Pump (B) 11 Seer heat pump units. Changed from 26" fan blade to
22" fan blade to improve operating sound.
PHB**CC2E P1228101C-P1228103C
P
ackage
H
eat Pump (
B
) 11 Seer heat pump units. New chassis design with smaller
footprint. With 10 K.W. factory installed heat strips.
PHB**CC2E P1235801C-P1235803C
P
ackage
H
eat Pump (
B
) 11 Seer heat pump units. Changed to Ranco Defrost
Board. Moved low pressure switch to suction side.
PHB**C02E P1235601C-P1235606C
P
ackage
H
eat Pump (
B
) 11 Seer heat pump units. Changed to Ranco Defrost
Board. Moved low pressure switch to suction side.
PHB**C02E1 P1239207C-P1239212C
P
ackage Heat Pump (B) 11 Seer heat pump units. Tubing redesigned to improve
serviceability and reduce the potential for distributor tubes rubbing and leaking.
PHB**CC2E1 P1239904C-P1239906C
P
ackage
H
eat Pump (
B
) 11 Seer heat pump units. Tubing redesigned to improve
serviceability and reduce the potential for distributor tubes rubbing and leaking.
PHB**C02E1 P1239214C-P1239219C
P
ackage Heat Pump (B) 11 Seer heat pump units. Change to UTEC Defrost Board.
Moved low pressure switch to liquid line and changed pressure setting from 5 PSIG
to 15 PSIG. Moved ECM interface board to return air section.
PHB**CC2E1
P1239908C-P1239910C
P1240008C-P1240010C
P
ackage Heat Pump (B) 11 Seer heat pump units. Change to UTEC Defrost Board.
Moved low pressure switch to liquid line and changed pressure setting from 5 PSIG
to 15 PSIG. Moved ECM interface board to return air section.
PHB**C02F1 P1239220C-P1239225C
P
ackage
H
eat Pump (
B
) 11 Seer heat pump units. Changed from tan to new
corporate colors.
PHB**CC2F1 P1239911C-P1239913C
P
ackage
H
eat Pump (
B
) 11 Seer heat pump units. Changed from tan to new
corporate colors.
PHD**C02E P1224301C-P1224305C
P
ackage Heat Pump (D) 13 Seer heat pump units. New chassis design with smaller
footprint.
PHD**C02E P1235701C-P1235705C
P
ackage
H
eat Pump (
D
) 13 Seer heat pump units. Changed to Ranco Defrost
Board. Moved low pressure switch to suction side.
PHD**CC2E P1228201C-P1228203C
P
ackage
H
eat Pump (
D
) 13 Seer heat pump units. New chassis design with smaller
footprint. With 10 K.W. factory installed heat strips.
PHD**CC2E P1235901C-P1235903C
P
ackage
H
eat Pump (
D
) 13 Seer heat pump units. Changed to Ranco Defrost
Board. Moved low pressure switch to suction side.
PHD**C02E1 P1239706C-P1239710C
P
ackage Heat Pump (D) 13 Seer heat pump units. Tubing redesigned to improve
serviceability and reduce the potential for distributor tubes rubbing and leaking.
PHD**CC2E1 P1240004C-P1240006C
P
ackage
H
eat Pump (
D
) 13 Seer heat pump units. Tubing redesigned to improve
serviceability and reduce the potential for distributor tubes rubbing and leaking.
PHD**C02E1 P1239711C P
ackage
H
eat Pump (
D
) 13 Seer heat pump units. Scroll compressor.
PHD**CC2E1 P1240007C
P
ackage Heat Pump (D) 13 Seer heat pump units. Scroll compressor.
PHD**C02F1 P1239718C-P1239723C
P
ackage Heat Pump (D) 13 Seer heat pump units. Changed from tan to new
corporate colors.
PHD**CC2F1 P1240011C-P1240013C
P
ackage Heat Pump (D) 13 Seer heat pump units. Changed from tan to new
corporate colors.
Model # Manufacturing # Description
PCC**C02E P1231101C-P1231106C
P
ackage
C
ooling (
C
) 12 Seer electric heat electric cooling units. New chassis design
with smaller footprint.
PCC**C02F P1231107-P1231112C
P
ackage
C
ooling (
C
) 12 Seer electric heat electric cooling units. Changed from tan
to new corporate colors.
PCA**C02E P1234801C-P1234806C
P
ackage
C
ooling (
A
) 10 Seer electric heat electric cooling units. Changed from tan
to new corporate colors.
PCA**C02F P1234807C-P1234811C
P
ackage Cooling (A) 10 Seer electric heat electric cooling units. New condenser
fan/motor.

Table of Contents

Other manuals for Amana PGB**C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Amana PGB**C and is the answer not in the manual?

Amana PGB**C Specifications

General IconGeneral
BrandAmana
ModelPGB**C
CategoryAir Conditioner
LanguageEnglish

Related product manuals