SS-DPTAC www.amana-ptac.com 7
6 www.amana-ptac.com SS-DPTAC
SPecification SHeet
SPecification SHeet
PtH modelS — reverSe-cycle Heating Performance
Heating Capacity¹
PTH 073B**A-
PTH
074B**A-
PTH
093B**AM
PTH
094B**AM
PTH
123B**AM
PTH
124B**AM
PTH
153B**AM
PTH
154B**AM
BTU/h
5
M Models
M=6,200/
6,000
M = 6,200 8,200/ 8,000 8,200
10,800/
10,600
10,800
13,300/
13,200
13,300
N Models
N=6,400/
6,300
N = 6,200 --- --- --- --- --- ---
Amps¹² 2.6/ 3.0 2.2 3.2/ 3.6 2.6 4.5/ 5.1 3.9 5.7/ 6.3 5.4
Watts¹² 550/ 530 550 750/ 730 750 1,020/ 1,000 1,020 1,340/ 1,330 1,340
COP
5
M Models
M= 3.3/ 3.3 M = 3.3 3.2 3.2 3.1 3.1 2.9 2.9
N Models
N= 3.5/ 3.6 N = 3.5 --- --- --- --- --- ---
CFM (Dry) 235/ 230 235 235/ 230 230 310/ 290 310 345/ 335 345
Heating
(BTU/h)
5
Outdoor
Ambient
Rating
Point
62 °F 7,200/ 7,000 7,200 9,800/ 9,600 9,800
13,000/
12,800
13,000
15,800/
15,700
15,800
57 °F 6,900/ 6,700 6,900 9,300/ 9,100 9,300
12,300/
12,100
12,300
15,000/
14,900
15,000
52 °F 6,500/ 6,300 6,500 8,700/ 8,500 8,700
11,600/
11,400
11,600
14,200/
14,100
14,200
47 °F 6,200/ 6,000 6,200 8,200/ 8,000 8,200
10,800/
10,600
10,800
13,300/
13,200
13,300
COP* 3.3/ 3.3 3.3 3.2/ 3.2 3.2 3.1/ 3.1 3.1 2.9/ 2.9 2.9
42 °F 5,900/ 5,700 5,900 7,700/ 7,500 7,700
10,100/
9,900
10,100
12,500/
12,400
12,500
37 °F 5,600/ 5,400 5,500 7,200/ 7,000 7,200 9,400/ 9,200 9,400
11,700/
11,600
11,700
32 °F 5,300/ 5,100 5,200 6,700/ 6,500 6,700 8,600/ 8,400 8,600
10,800/
10,700
10,800
27 °F 5,000/ 4,800 5,000 6,200/ 6,000 6,200 7,900/ 7,700 7,900
10,000/
9,900
10,000
24 °F 4,800/ 4,600 4,800 5,900/ 5,700 5,900 7,500/ 7,300 7,500 9,500/ 9,400 9,500
Watts
Outdoor
Ambient
62 °F 580/ 560 580 810/ 790 810 1,120/ 1,100 1,120 1,465/ 1,455 1,465
57 °F 575/ 555 575 800/ 780 800 1,090/ 1,075 1,090 1,440/ 1,430 1,440
52 °F 555/ 535 555 775/ 755 775 1,060/ 1,045 1,060 1,405/ 1,395 1,405
47 °F 550/ 530 550 750/ 730 750 1,020/ 1,005 1,020 1,340/ 1,330 1,340
42 °F 540/ 525 560 730/ 710 730 985/ 970 985 1,325/ 1,315 1,325
37 °F 530/ 515 545 705/ 685 705 950/ 935 950 1,285/ 1,275 1,285
32 °F 515/ 500 535 690/ 670 690 900/ 885 900 1,240/ 1,230 1,240
27 °F 505/ 490 525 660/ 640 660 855/ 840 855 1,190/ 1,180 1,190
24 °F 500/ 485 520 640/ 620 640 830/ 815 830 1,180/ 1,170 1,180
- Denotes M or N models
COP = Coefciency of Performance; per ARI Test Procedures, units are rated for capacities and efciencies.
See Page 6 for Notes and Auxiliary Electric Heater Performance.
Product SPecificationS (cont.)