NOTICE
If an overload is detected the product stops operation and the
OVERLOAD indicator (F) lights up and the product beeps. Switch
off the product and unplug at least one connected equipment so
that the maximum capacity is not exceeded. Wait 10 seconds and
press the RESET button (L). Then switch on the product again.
Surge protection outlets (K)
The outlets (K) provide only surge protection. Those outlets do not provide power
during a power outage.
NOTICE
The surge protection (K) are constantly on, whenever the product is
connected to the power supply.
NOTICE
The upper 2 outlets are positioned away from the other outlets in
order to allow bulky AC power adapters to be connected.
Status
1. Power outage The product operates in the battery backup mode.
2. Low battery
The battery capacity is low. The battery will be drained
quickly during power outage.
3. Overload
Product rated capacity is exceeded. Switch off the
product and unplug at least one connected equipment
so that the maximum capacity is not exceeded. Wait 10
seconds and press the RESET button (L). Then switch on
the product again.
4. Short fault
Switch off the product and unplug at least one connected
equipment from the battery backup outlets. Then switch
on the product again.
5. Charge fault
The battery charging voltage is too high or too low.
Contact professional repair centre.