EasyManua.ls Logo

American Standard 4A6L5048N1000A User Manual

American Standard 4A6L5048N1000A
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SSAAFFEETTYY WWAARRNNIINNGG
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
June 2022 1111--BBCC4466DD11--11AA--EENN
Side Discharge HP Models
For coastal applications where units are installed within one (1) mile of salt water, epoxy coated models are recommended. These models
have an 8 week lead time after order.
EEppooxxyy CCooaatteedd MMooddeell
4A6L5024N1000A
4A6L5030N1000A
4A6L5036N1000A
4A6L5042N1000A
4A6L5048N1000A
4A6L5024N1COTA
4A6L5030N1COTA
4A6L5036N1COTA
4A6L5042N1COTA
4A6L5048N1COTA
NNoottee:: “Graphics in this document are for representation
only. Actual model may differ in appearance.”
Installer’s Guide

Questions and Answers:

American Standard 4A6L5048N1000A Specifications

General IconGeneral
BrandAmerican Standard
TypeHeat Pump
Model Number4A6L5048N1000A
SEER Rating16
RefrigerantR-410A
Voltage208/230V
Phase1
Cooling Capacity (BTU/h)48000
Heating Capacity (BTU/h)48000
Cooling Capacity4 Tons
HSPF Rating9.0
Compressor TypeSingle Stage

Summary

Installer's Guide

Safety Warning

General safety warning for installation and service personnel.

SAFETY SECTION

Safety Warnings and Cautions

Covers hazardous voltage, refrigerant, hot surfaces, grounding, service valves, and chemical exposure warnings.

Refrigerant Line Considerations

Brazing Refrigerant Lines

Step-by-step instructions for brazing refrigerant lines.

Refrigerant Line Leak Check and Evacuation

Procedure for performing a leak check and evacuating refrigerant lines and the indoor coil.

Electrical — Low Voltage Non Communicating

Electrical — High Voltage

High Voltage Power Supply

Requirements and safety precautions for the high voltage power supply.

High Voltage Disconnect Switch

Installation and safety guidelines for a separate high voltage disconnect switch.

Grounding Requirements

Ensuring proper grounding of the outdoor unit per national, state, and local codes.

Subcooling Charging in Cooling between 55° F and 120° OD Ambient

Subcooling Charging Method

Recommended subcooling method for charging above 55° F ambient temperatures.

Charging the Unit

Checkout Procedures

Troubleshooting

Compressor Fails to Start Troubleshooting

Troubleshooting steps when the compressor fails to start, checking contactors and voltage.

Compressor Won't Run Troubleshooting

Diagnostic steps for a compressor that won't run, checking voltage, windings, and start components.

Related product manuals