SSAAFFEETTYY WWAARRNNIINNGG
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
August 2022
44AA--VV00XX--SSFF--11CC--EENN
American Standard Link or AccuLink
Variable Speed Heat Pumps and Air Conditioners
4A6V0X24A1000A
4A6V0X36A1000A
4A6V0X48A1000A
4A6V0X60A1000A
4A7V0X24A1000A
4A7V0X36B1000A
4A7V0X48A1000A
4A7V0X60A1000A
4A7V0X61A1000A
TM
The Diagnostics Mobile App is available by scanning a QR code
located inside this unit or by searching for the Link Diagnostics App
in your App Store
®
.
NNoottee:: “Graphics in this document are for representation only. Actual
model may differ in appearance.”
NNoottee:: This unit can be used in AccuLink
mode or American Standard
Link mode.
Service Facts

Other manuals for American Standard AccuLink 4A6V0X36A1000A

Question and Answer IconNeed help?

Do you have a question about the American Standard AccuLink 4A6V0X36A1000A and is the answer not in the manual?

American Standard AccuLink 4A6V0X36A1000A Specifications

General IconGeneral
Model4A6V0X36A1000A
BrandAmerican Standard
Cooling Capacity36, 000 BTU
Tonnage3 Ton
SEER Rating16
RefrigerantR-410A
System TypeSplit System
Voltage208/230V
Phase1
TypeAir Conditioner
Compressor TypeScroll
Warranty10 Years
HSPF9.0
StagesSingle-Stage
Energy Efficiency Ratio (EER)Up to 13 EER

Summary

Service Facts and Safety Introduction

General Safety Warnings

Comprehensive safety precautions including electrical, refrigerant, and hot surface hazards.

400 Volts Electrical Hazard

Specific warning about dangerous 400VDC charge in electrical components after power disconnection.

Product Specifications

Charging Procedures

Subcooling Charging and Corrections

Method for subcooling charging and charts for line length/lift corrections.

System Wiring and Control

Wiring Diagram and Legend

Schematic showing electrical connections, components, and wire colors.

Integrated Variable Speed Control (IVSC)

IVSC inputs, outputs, LED indicators, and connections.

Sequence of Operation

Defrost Control

Sensors and Transducers

Variable Speed Alert Codes

Alert Code Reference

Comprehensive list of alert codes, descriptions, and possible causes.

Refrigeration Circuits

Load Shedding and Communication

Communication Loss Troubleshooting

Flowchart for diagnosing and resolving communication loss issues.

Troubleshooting Procedures

Breaker Trip and Compressor Start Issues

Flowcharts for breaker trips, compressor start, and verification steps.