RECOMMENDED TOOLS AND MATERIALS
Putty Knife Regular Screwdriver Adjustable Wrench Sealant Tape Measure
Hacksaw Wax Ring/Gasket Flexible Supply Tube Closet Bolts Carpenters Level
1 REMOVE OLD TOILET
a. Close toilet supply valve and flush tank completely. Towel or sponge remaining water from tank and bowl.
b. Disconnect and remove supply line. NOTE: If replacing valve, first shut off main water supply!
c. Remove old mounting hardware, remove toilet and plug floor waste opening to prevent escaping sewer gases.
d. Remove closet bolts from flange and clean away old wax, putty, etc. from base area.
NOTE: Mounting surface must be clean and level before new toilet is installed!
SAVE FOR FUTURE USE
730928-100 Rev. K
CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE!
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2009
NOTE: Pictures may not exactly define contour of china and components.
CADET
®
3 - 1.6 GPF TWO-PIECE TOILET
Models 2383 / 2384 / 2386 / 2447 / 2431 / 2880 / 3305 / 2852
CADET
®
3 FloWise™ - 1.28 GPF TWO-PIECE TOILET
Models 2829 / 2832 / 2835 / 2838 / 2880 / 3305 / 2447 / 2852 /
3329 / 3339 / 3377 / 3378 / 3379
INSTALLATION INSTRUCTIONS
CARE AND MAINTENANCE
Thank you for selecting American Standard - the benchmark of fine quality for over 100 years. To ensure this product is
installed properly, please read these instructions carefully before you begin. (Certain installations may require professional
help.) Also be sure your installation conforms to local codes.
2
CLOSET
FLANGE
CLOSET
BOLTS
A
FINISHED WALL
FINISHED
FLOOR
SUPPLY
AS
REQ'D.
A
WAX RING
SEALANT
5
43
INSTALL WAX SEAL
Invert toilet on floor (cushion to prevent
damage), and install wax ring evenly
around waste flange (horn), with tapered
end of ring facing toilet. Apply a thin bead
of sealant around toilet base.
POSITION TOILET ON FLANGE
a. Unplug floor waste opening and install toilet on closet flange
so bolts project through mounting holes.
b. Loosely install retainer washers and nuts. Side of washers
marked "THIS SIDE UP" must face up!
CLOSET
BOLT
NUT
TAPERED
WASHER
FLANGE
ROUGHING-IN DIMENSIONS:
NOTE: Distance from wall to closet flange centerline must be as listed on chart:
INSTALL CLOSET BOLTS
Install closet bolts in flange
channel, turn 90
°
, and slide
into place 6" (152mm) apart
and parallel to wall.
!
MODELS
DIMENSION “A”
10"
ROUGHS
12"
ROUGHS
14"
ROUGHS
254mm (10)
305mm (12)
356mm (14)
2383.012
2386.012
2384.012
3305.000
2431.012
2447.000
2880.000
3377.128
3378.128
2829.128
2832.128
2835.128
2838.128
2852.000
2852.128
2447.128
2880.128
3329.128
3339.128
2383.010 2384.010
2386.010 3379.128
2383.014 2384.014
2386.014
Question and Answer IconNeed help?

Do you have a question about the American Standard Cadet 3 2383 and is the answer not in the manual?

Summary

Remove Old Toilet

Roughing-In Dimensions

Install Closet Bolts

Install Wax Seal

Position Toilet on Flange

Install Toilet

Install Tank

Install Toilet Seat

Water Supply Connection Types

Metal;Copper Flared Tubing

Details connection for metal or copper flared tubing with lock nut and coupling nut.

Metal Flanged Tubing

Details connection for metal flanged tubing using existing coupling nut and washer.

Metal Spiral Tubing

Details connection for metal spiral tubing using cone washer and coupling nut.

Vinyl;Braided Connector

Details connection for vinyl or braided supply lines with captive cone washers.

Water Supply Connection Tightening

Adjustments

Adjust Water Level

Guide on adjusting the water level in the tank using the float cup.

Adjust Lift Chain

Procedure for adjusting the lift chain to improve bowl siphoning.

Water Level Adjustment

Care and Cleaning

Troubleshooting

Fill Valve Leaking Slowly

Steps to address a fill valve that shuts off but continues to leak slowly.

Fill Valve Cycling During Non-Use

Troubleshooting fill valve cycling, indicating potential water waste.

Fill Valve Not Turning On;Off

Solutions for fill valve issues with slow tank refilling or failure to operate.

Troubleshooting Guide

Does Not Flush

Identifies causes and corrective actions for toilets that do not flush.

Poor or Sluggish Flush

Addresses issues causing a weak or sluggish toilet flush.

Toilet Leaks

Diagnoses and fixes for common toilet leak problems.

Toilet Does Not Shut Off

Solutions for toilets that fail to shut off after flushing.

Repair Parts List

Overview

This document provides installation, care, and maintenance instructions for the American Standard Cadet® 3 two-piece toilets, including both 1.6 GPF (Gallons Per Flush) and 1.28 GPF FloWise™ models.

Function Description:

The Cadet® 3 is a two-piece toilet system designed for efficient flushing. It consists of a bowl and a tank, which are assembled during installation. The toilet utilizes a gravity-fed flushing system, with water stored in the tank and released into the bowl to clear waste. The FloWise™ models are designed for water conservation, using less water per flush. The system includes a fill valve to replenish water in the tank after each flush and a flush valve with a flapper mechanism to initiate the flush.

Important Technical Specifications:

  • Models Covered:
    • 1.6 GPF: 2383 / 2384 / 2386 / 2447 / 2431 / 2880 / 3305 / 2852
    • 1.28 GPF FloWise™: 2829 / 2832 / 2835 / 2838 / 2880 / 3305 / 2447 / 2852 / 3329 / 3339 / 3377 / 3378 / 3379
  • Roughing-in Dimensions (Distance from wall to closet flange centerline):
    • 10 inches (254mm) for models 2383.010, 2384.010, 2386.010, 3379.128
    • 12 inches (305mm) for models 2383.012, 2829.128, 2386.012, 2832.128, 2384.012, 2835.128, 3305.000, 2838.128, 2431.012, 2852.000, 2447.000, 2852.128, 2880.000, 2447.128, 3377.128, 2880.128, 3378.128, 3329.128, 3339.128
    • 14 inches (356mm) for models 2383.014, 2384.014, 2386.014
  • Minimum Supply Pressure: Normal supply pressure must be at least 20 psi.
  • Water Level Adjustment: The critical water level mark ("C.L.") in the tank must be 1 inch above the overflow pipe. Water level is adjusted by turning the WATER LEVEL ADJUSTMENT ROD and moving the FLOAT CUP up or down.
  • Tank Mounting: For Speed Connect System, tank mounting bolts are pre-installed. A large rubber gasket ensures a seal between the tank and bowl.
  • Water Supply Connection: Various connection types are supported, including metal/copper flared tubing, metal flanged tubing, metal spiral tubing, and vinyl/braided connectors. Specific washers and nuts are required for each type.

Usage Features:

  • Two-Piece Design: Allows for easier handling and installation compared to one-piece toilets.
  • Efficient Flushing System: Designed to effectively clear waste with either 1.6 GPF or 1.28 GPF, depending on the model.
  • Water Conservation (FloWise™ models): The 1.28 GPF models contribute to reduced water usage.
  • Adjustable Water Level: Users can fine-tune the water level in the tank to optimize flush performance and water usage.
  • Adjustable Lift Chain: If the bowl fails to siphon, the lift chain can be adjusted to ensure proper flapper operation.

Maintenance Features:

  • Cleaning:
    • Use mild, soapy water, rinse thoroughly with clear water, and dry with a soft cloth.
    • WARNING: Avoid detergents, disinfectants, or cleaning products in aerosol cans. NEVER use abrasive scouring powders or abrasive pads on the toilet seat, as they can damage the finish.
    • WARNING: Do not use in-tank cleaners, especially those containing chlorine (calcium hypochlorite), as they can seriously damage tank fittings, leading to leaks and property damage. American Standard is not responsible for damage caused by such cleaners.
  • Troubleshooting Guide: The manual includes a comprehensive guide for common issues:
    • Does not flush: Check supply valve, supply line blockage, flush valve chain, or debris in water control.
    • Poor or sluggish flush: Check bowl water level, supply valve, trapway/drain pipe/vent, or supply pressure.
    • Toilet leaks: Review supply line connection and bowl-to-tank/floor connection.
    • Toilet does not shut off: Check flush valve chain, worn flapper/seat, or debris in water control.
  • Fill Valve Maintenance (Fluidmaster 400A Inlet):
    • If the fill valve leaks slowly or turns off and on during non-use periods, it indicates a problem.
    • To clear sand and rust: Turn off water supply, remove the valve top by lifting the arm and rotating 1/8 turn counterclockwise, pressing down slightly. Briefly turn water supply on and off over a container, then replace the top by rotating 1/8 turn clockwise until locked.
    • If the fill valve won't turn on or shut off, or refill is slow, a Fluidmaster Model 242 Replacement Seal may be needed.
  • Repair Parts List: A detailed list of replacement parts is provided, categorized by 1.6 GPF and 1.28 GPF models, including tank levers, bolt cap kits, fill valves, flush valves, flapper assemblies, refill tubes, and tank covers. This allows for easy identification and ordering of necessary components.
  • Water Supply Connection Warning: Do not use plumber's putty, pipe dope, or any other sealant on the water supply connection to the tank. If leaks persist after hand tightening, replace the supply line or the fill valve. Warranty is void if sealant is used on the water supply connection.

American Standard Cadet 3 2383 Specifications

General IconGeneral
BrandAmerican Standard
ModelCadet 3 2383
CategoryPlumbing Product
LanguageEnglish