EasyManua.ls Logo

American Standard Jasmine Amarilis 3821.831 User Manual

American Standard Jasmine Amarilis 3821.831
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
HI-FLOW
KITCHEN FAUCET
Installation
Instructions
Certified to comply with ANSI A112.18.1M
M968150 REV. 1.1
3821.831
3821.834
1
This faucet permits an interchangeable mounting of each integral
component -- spout, valve, and hand spray -- to suit the particular
installation requirements.
Remove LOCKNUT (1) and RETAINER PLATE (2).
Insert SUPPLY TUBES
(3), SPOUT HOSE (4) and
THREADED STUD
(5) through hole in SINK.
Make sure O-RING
(6) is properly seated in recess of BASE.
Orient VALVE
(7) so that two inlets tubes face towards the front.
Assemble RETAINER PLATE
(2) and LOCKNUT (1) onto
STUD
(5) from underside of SINK.
Hand tighten LOCKNUT
(1) and check that rotation of HANDLE
from HOT to COLD is centered. Secure VALVE
(7) position by
tightening LOCKNUT
(1) firmly. (Spread TUBES for better
access to LOCKNUT).
Bend TUBES
(3) to meet supplies. Use palm of hand to support
TUBES
(3) while bending to avoid kinking.
Before starting installation, place each component loosely
into the holes of the kitchen sink to select the most desirable
arrangement.
ROUGHING-IN DIMENSIONS
9-3/8
8-5/8
13
1-1/16
MAX
1-1/4 MAX
1-1 /4 MAX
13/16
DIA
HOT COLD
3/8 OD COPPER
BENDABLE
C/L OF
FLEXIBLE HOSE
TO SPOUT
SPRAY
HOSE
VALVE
1-1/4
MIN. DIA
MTG HOLE
2 DIA.
7-1/8
10 MAX
2-1/2
DIA.
MTG
SURFACE
27/32
DIA.
2 DIA.
10" MAX
VALVE INSTALLATION
SPRAY HOSE
SPOUT HOSE
SINK
1
2
3
4
5
6
7
0
1
2
3
4
5
6
Thank you for selecting American-Standard...
the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--
please read these instructions carefully before you begin.
TOOLS REQUIRED
Plumbers' Putty or Caulking
Adjustable WrenchChannel Locks Regular Screwdriver
Phillips ScrewdriverPhillips Screwdriver
Turn off water at
main supply.
CAUTION
Question and Answer IconNeed help?

Do you have a question about the American Standard Jasmine Amarilis 3821.831 and is the answer not in the manual?

American Standard Jasmine Amarilis 3821.831 Specifications

General IconGeneral
BrandAmerican Standard
ModelJasmine Amarilis 3821.831
CategoryPlumbing Product
LanguageEnglish

Summary

Valve Installation

Remove Locknut and Retainer Plate

Remove locknut and retainer plate before inserting supply tubes.

Insert Supply Tubes, Spout Hose, and Threaded Stud

Insert supply tubes, spout hose, and threaded stud through the sink hole.

Seat O-Ring in Base Recess

Ensure the O-ring is correctly seated in the base recess.

Orient Valve Inlets

Position the valve with inlet tubes facing the front.

Assemble Retainer Plate and Locknut

Assemble retainer plate and locknut onto the stud from under the sink.

Tighten Locknut and Center Handle Rotation

Hand-tighten locknut, check handle rotation centering for hot to cold.

Bend Tubes to Meet Supplies

Bend tubes carefully to meet supplies, supporting them to prevent kinking.

Spout Installation

Insert Spout Shank

Insert the spout shank through the designated sink hole.

Seat Rubber Ring in Escutcheon

Ensure the rubber ring is seated correctly in the escutcheon recess.

Center Escutcheon and Tighten

Center the spout escutcheon and firmly tighten the wing nut.

Connect Spout Hose

Connect the spout hose to the spout shank.

Hand Spray Installation

Install Spray Holder

Place spray holder in sink, attach wing nut to shank from underside.

Connect Spray Hose to Valve

Feed spray hose through holder and attach coupling to valve's threaded stud.

Tighten Coupling Nut

Firmly tighten the coupling nut.

Attach Washers and Spray Head

Attach washers to hose, then thread spray head to nut.

Connect Supplies

Bend Tubes Carefully

Bend tubes to connect to supplies, supporting them to prevent kinking.

Connect Inlet Tubes to Water Supplies

Connect 3/8-inch OD inlet tubes to water supplies using connectors.

Connect Left to Hot, Right to Cold

Connect the left tube to the hot water supply and the right tube to cold.

Test Installed Faucet

Prepare for Testing

Move handle to off, and remove the aerator before testing.

Check Connections for Leaks

Turn on water supplies and check all connections for leaks.

Flush Lines and Check Spout

Flush water lines and check spout mounting for leaks.

Activate Spray and Check Hose

Activate spray and check spray hose connections for leaks.

Finalize Testing

Move handle to off and replace aerator.

Service and Maintenance

Clean Aerator

Remove aerator to clean dirt causing distorted water flow.

Address Spout Drips

Operate handles several times from OFF to ON to address spout drips.

Hot Limit Safety Stop Adjustment

Purpose of Hot Limit Stop

Reduces risk of scalding by limiting hot water mixed with cold.

Adjust Temperature Setting

Remove handle, pull cap, and rotate red stop to adjust temperature.

Reassemble Faucet Components

Replace escutcheon cap, handle, tighten screw, and install index button.