Do you have a question about the American Standard Jasmine Amarilis 3821.831 and is the answer not in the manual?
Brand | American Standard |
---|---|
Model | Jasmine Amarilis 3821.831 |
Category | Plumbing Product |
Language | English |
Remove locknut and retainer plate before inserting supply tubes.
Insert supply tubes, spout hose, and threaded stud through the sink hole.
Ensure the O-ring is correctly seated in the base recess.
Position the valve with inlet tubes facing the front.
Assemble retainer plate and locknut onto the stud from under the sink.
Hand-tighten locknut, check handle rotation centering for hot to cold.
Bend tubes carefully to meet supplies, supporting them to prevent kinking.
Insert the spout shank through the designated sink hole.
Ensure the rubber ring is seated correctly in the escutcheon recess.
Center the spout escutcheon and firmly tighten the wing nut.
Connect the spout hose to the spout shank.
Place spray holder in sink, attach wing nut to shank from underside.
Feed spray hose through holder and attach coupling to valve's threaded stud.
Firmly tighten the coupling nut.
Attach washers to hose, then thread spray head to nut.
Bend tubes to connect to supplies, supporting them to prevent kinking.
Connect 3/8-inch OD inlet tubes to water supplies using connectors.
Connect the left tube to the hot water supply and the right tube to cold.
Move handle to off, and remove the aerator before testing.
Turn on water supplies and check all connections for leaks.
Flush water lines and check spout mounting for leaks.
Activate spray and check spray hose connections for leaks.
Move handle to off and replace aerator.
Remove aerator to clean dirt causing distorted water flow.
Operate handles several times from OFF to ON to address spout drips.
Reduces risk of scalding by limiting hot water mixed with cold.
Remove handle, pull cap, and rotate red stop to adjust temperature.
Replace escutcheon cap, handle, tighten screw, and install index button.