SLOT
MOUNTING
SURFACE
Turn off hot and cold water
supplies before beginning.
CAUTION
Insert SPOUT (1) and CABLE CONNECTOR (14) through center hole, making sure
the SPOUT ESCUTCHEON (2) and SEAL WASHER (3) are properly seated.
Assemble RUBBER WASHER (4), BRASS WASHER (5) and LOCKNUT (6) onto SPOUT
SHANK (7) from under side of sink . Make sure SPOUT (1) is centered in the mounting
hole and the slot in the BRASS WASHER (5) faces toward the rear of the sink.
Tighten LOCKNUT (6) firmly. Fig. A.
Tighten LOCKNUT (11) with WRENCH (8) (supplied) to secure VALVE
BODY (13). Repeat above steps for opposite VALVE BODY (13A).
Install LOCKNUT (11) and RUBBER WASHER (12) onto VALVE BODY (13).
From under side of mounting surface, install VALVE BODY (13) through valve
mounting holes. Threads of VALVE BODY (13) should extent at least 5/16
of a inch above mounting surface top. Fig. B. Thread DECK ADAPTER (10)
onto VALVE BODY (13) until snug against internal stop. If necessary, adjust
LOCKNUT (11).
1
1A
Certified to comply with ANSI A112.18.1
Installation
Instructions
INSTALL SPOUT
INSTALL VALVE BODY
1
2
1
8
10
9
12
11
13
13a
10
9
12
11
3
Place RUBBER RING (9) into DECK ADAPTER (10).
13
5/16'' MIN.
7
Adjustable Wrench Screwdriver Channel Locks
Recommended tools
Tubing Cutter
Fig. A.
Fig. B.
1
AMARILIS
3801.000
3841.000
Spread Lavatory Faucet with
Speed Connect™ Drain
43167 Rev. 1.3
JASMINE
SPOUT
IRIS
SPOUT
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
*Your new American Standard faucet is designed to work only with the Speed Connect drain. Heplful tips for
removing your current drain can be found in the Troubleshooting section of these instructions.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Speed Connect™ Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
Question and Answer IconNeed help?

Do you have a question about the American Standard Amarilis 3801.000 and is the answer not in the manual?

American Standard Amarilis 3801.000 Specifications

General IconGeneral
Product TypeToilet
ColorWhite
MaterialVitreous China
Water Consumption1.6 gpf
BrandAmerican Standard
Bowl ShapeElongated
Rough-In12 inches
Flush Valve Size2 inches
Trapway Size2 inches
Flush TypeGravity
Model Number3801.000
TypeTwo-Piece
Flush Rate1.6 gallons per flush (gpf)
Rough-In Size12 inches

Summary

Install Spout

Install Valve Body

Pop-Up Drain

Remove Flange

Install Drain from Below Fixture

Tighten Locknut

Flange Gasket and Pop-Up Knob

Attach Cable Connector

Check Operation of Pop-Up

Make Water Supply and Waste Connections

Install Handles

Test Installed Fitting

Check Drain Connections

Care Instructions

Service

Speed Connect Drain Troubleshooting Guide

Cable Adjustment Procedure

Procedure to adjust the drain cable for proper stopper operation and water holding.

Stopper Removal Procedure

Steps to remove the stopper from the drain assembly.

Stopper Installation Procedure

Locked Mode

Install stopper so it cannot be removed for vandal-proof functionality.

Unlocked Mode

Install stopper to allow for easy removal.