Ensure the seal is correctly positioned in the spout base recess before installation.
Pass hoses and shank through the mounting ring and surface without using putty.
Connect hoses, washers, and locknut to the shank from the underside and hand-tighten.
Secure the locknut using screws, tightening evenly for consistent pressure.
Connect hot and cold water supplies to the fittings, tightening with an adjustable wrench.
Loop hoses if too long to prevent kinking; purchase additional length if needed.
Install the weight onto the spray hose approximately two feet from the sink deck.
Connect the spray hose to the coupling nut, ensuring the seal washer is in place.
Operate the faucet handle through hot and cold positions to flush lines.
Test the toggle button to switch between stream and spray modes.
Operate handle multiple times; clean flow control device if dirt accumulates.
Disassemble to clean cartridge, manifold, and seals for reduced flow issues.
Rinse with clear water and dry with a soft cotton cloth; avoid harsh cleaners.