Provides essential background and safety guidelines before starting installation or operation.
Detailed steps for safely lifting and positioning the unit onto a roof curb.
Procedure for checking and adjusting the unit's gas input rate and manifold pressure.
Guidelines for proper electrical wiring, grounding, and power supply connections.
Essential checks to perform before starting the unit for the first time.
Steps for initiating operation of the unit in cooling mode.
Comprehensive list of checks to ensure the unit is installed and ready for operation.
Describes the step-by-step process the unit follows during a heating call.
Explains the sequence of events when the unit operates in cooling mode.
Provides essential background and safety guidelines before starting installation or operation.
Detailed steps for safely lifting and positioning the unit onto a roof curb.
Procedure for checking and adjusting the unit's gas input rate and manifold pressure.
Guidelines for proper electrical wiring, grounding, and power supply connections.
Essential checks to perform before starting the unit for the first time.
Steps for initiating operation of the unit in cooling mode.
Comprehensive list of checks to ensure the unit is installed and ready for operation.
Describes the step-by-step process the unit follows during a heating call.
Explains the sequence of events when the unit operates in cooling mode.
This document outlines the installation, operation, and maintenance procedures for Trane/American Standard Packaged Convertible Gas/Electric units, specifically models YCC018-060F. These units are designed for outdoor mounting with a vertical condenser discharge and can be installed at ground level or on a roof. They are suitable for both residential and commercial applications, with specific warranty terms for each.
The YCC018-060F series units provide both heating and cooling functions. They are gas/electric packaged units, meaning all components for both heating (gas furnace) and cooling (electric air conditioner) are housed within a single outdoor cabinet. The units are shipped configured for natural gas only, but can be converted for propane use. They are designed for either horizontal or downflow airflow applications, with instructions provided for converting between these configurations. The heating cycle is controlled by a solid-state ignition system, and the cooling cycle utilizes a compressor and outdoor/indoor fan motors.