Do you have a question about the Ameristar M4CXC060BD1CAAA and is the answer not in the manual?
Brand | Ameristar |
---|---|
Model | M4CXC060BD1CAAA |
Category | Air Conditioner |
Cooling Capacity | 5 Tons |
Refrigerant | R-410A |
Compressor Type | Scroll |
Voltage | 208/230 |
Phase | 1 |
Frequency | 60 Hz |
Sound Level (Outdoor Unit) | 76 dB |
Cooling Capacity (BTU) | 60000 BTU |
Inspect unit for damage upon receipt; note issues on delivery receipt and contact carrier.
Select suitable location for indoor/outdoor units, observing limitations and clearance requirements.
Install unit on a level, solid base that will not shift or settle, maintaining clearances.
Provide base, inspect for damage, keep compressor tie-downs tight, position unit on base.
Elevate unit on flat roof/slab using stringers for weight distribution and vibration prevention.
Secure unit to slab using L-brackets and concrete screws for high wind areas.
Install lines with minimal bends, avoid kinks, insulate suction line, use PVC for underground runs.
Use phosphorous-copper alloy for brazing; use dry nitrogen to prevent oxidation during brazing.
Wire units according to National and Local Safety Codes and wiring diagrams.