Sequoia / Tahoe Series User Manual California Instruments
M447352-01 REV-A 195
The UP arrow button will return to the previously selected screen menu (in this case the HOME Screen-
1). The HOME button will return to the HOME screen that has the top-level menu for the sub-menu being
displayed; for the DASHBOARD screen top-level menu, that is the HOME Screen.
3-Phase
1-Phase
Figure 5-168. DASHBOARD Screen Top-Level Menu
The following selections are available in the DASHBOARD screen top-level menu. Functions that
accept a numeric value require that the value is within the allowed range, otherwise, an error will
be generated, and the value will not be accepted.
When the unit is configured for 3-Phase output, each phase has individual settings. When the unit
is configured for 1-Phase output, only Phase-A is displayed. Tapping on a phase button toggles
the selection of that phase for inputting values. When a phase is selected, its button is displayed
with a green color. When a phase is not selected, its button is displayed with a gray color. When
all phases are selected, entry for one phase will make the same changes for the other phases.
Entry Description
Setting
Active Power Programs the Active power required as a load for the UUT.
Re-Active Power Programs the Reactive Power is required as a load for the UUT.
RANGE Displays 166 VAC or 333 VAC range for AC-mode and 220 VDC
or 440 VDC range for DC-mode operation. The OUTPUT state
must be OFF for a change in range to be executed.
MODE Displays the source mode of operation.