Sequoia / Tahoe Series User Manual California Instruments
M447352-01 REV-A 231
ANALOG Selects the reference that determines the output voltage
waveform and amplitude; the default is INT. The options are as
follows:
INT: Selects programming of the output voltage waveform and
amplitude by the internal controller reference.
RPV: Selects programming of output voltage amplitude with an
external analog interface signal, with the waveform being set by
the internal controller reference. A Voltage field is provided for
entry of DC input signal range: user-selectable maximum range
value within 2.5 VDC to10 VDC, for full-scale RMS of the
internally programmed output voltage waveform.
EXT: Selects programming of the output voltage waveform and
amplitude with an external analog interface signal. A Voltage field
is provided for entry of AC or DC input signal range: 0V to
user-selectable maximum range value within 2.5 V(PK) to 10
V(PK), corresponding to the maximum range of 1.77 V(RMS) to
7.07 V(RMS), for zero to full-scale RMS output voltage; with AC
waveform, from 16 Hz to 5 kHz (option dependent).
NOTE: External Reference is not supported in eLOAD Mode.
Figure 5-240. CONTROL INTERFACE Menu, ANALOG Sub-
Menu
Figure 5-241: ANALOG Sub-Menu for eLoad-Current