Compares Lite, Silver, and Gold versions of TalyProfile software and their functions.
Provides details on languages, data output, storage, SPC/stats, and battery specifications.
Lists supported analysis standards including ISO 4287, ISO 13565, ASME B46.1, JIS B 0601.
Specifies the measurement range, resolution, noise floor, and repeatability for S-116 and S-128.
Declares conformity with EU Low Voltage, EMC, and RoHS directives.
Details basic operations including overview, menu navigation, icons, shortcuts, graph, battery, and memory.
Explains how to configure filter settings, including lambda type and cut-off.
Guides on setting evaluation length and selecting measurement parameters based on standards.
Instructions for turning the unit on/off and initiating measurements.
Step-by-step guide to accessing and scrolling through the instrument's menu.
How to adjust the lambda cut-off length using the shortcuts.
Guides on selecting the filter type (e.g., 2CR, Gaussian).
Step-by-step guide to select the filter lambda type.
Procedure for selecting the lambda cut-off size for filtering.
How to select and set the evaluation length for measurements.
Guides on selecting parameters based on ISO 4287 and other standards.
How to adjust the Rmr settings, including Mr% and Meanline.
Guides on adjusting the Mr% value using the on-screen keypad.
Procedure for adjusting the Mr% offset value, including sign and magnitude.
How to adjust the Meanline offset value using up/down arrows.
How to adjust the Rpc bandwidth value using the up/down arrows.
Guides on selecting the appropriate measurement range for the application.
How to select between Metric and English units for measurements.
Details how to access and configure calibration settings.
Instructions for entering and saving the calibration value using the numeric keypad.
How to select the required filter type for calibration.
Procedure for selecting the required cut-off value for calibration.
How to set calibration evaluation length and adjust lambda cut-off.
Steps to initiate and complete a calibration measurement on the instrument.
Details the different storage modes: Off, Internal, USB, and USB + Raw.
Steps to create a new batch for storing measurements, including naming conventions.
Guides on selecting print options like model, V. Scale, and graph inclusion.