Explains the rapid startup time from standby for immediate measurement.
Compares usability to SatNav/Smartphones with a clear touch screen display.
Overview of TalyProfile as a PC-based software for advanced surface finish analysis.
Details the three versions (Lite, Silver, Gold) and their features.
Details how profiles can be levelled, zoomed, and analyzed numerically or graphically.
Provides technical details on languages, data output, storage, SPC/stats, and battery.
Lists supported standards, ISO basic, ISO advanced, ASME, JIS, and Other parameters.
Details range, resolution, noise floor, repeatability, pickup type, gauge force, and stylus tip radius.
Explains the meaning and implications of the CE Mark on Taylor Hobson products.
Covers general device operation, including overview, menu, icons, shortcuts, graph, battery, and memory.
Details how to configure filter types, evaluation lengths, parameters, and measurement ranges.
Explains unit selection and the process for instrument calibration.
Explains storage modes: Off, Internal, USB, and USB + Raw.
Introduces the Power/Measure button and the instrument's display elements.
Guides users on how to navigate through the device's menu system.
Details how to adjust the λc Cut-off value for measurements.
Details how to select the filter type (e.g., 2CR, Gaussian).
Explains how to select the λc Cut-off size for filtering.
Guides on selecting the evaluation length and how it's automatically calculated.
Details how to choose parameters based on standards like ISO 4287.
Explains how to access and adjust Rmr settings, including Mr% and Meanline.
Guides on how to adjust the Mr% value using the up/down arrows.
Details how to adjust the Rmr offset value, including positive/negative selection.
Explains how to adjust the Meanline setting and offset.
Guides on adjusting the Rpc Bandwidth value.
Details how to select the measurement range (e.g., 10µm, 100µm, 400µm).
Guides on accessing calibration settings and options.
Details how to enter and save the calibration value using the keypad.
Explains how to choose the calibration filter type (e.g., 2CR, Gaussian).
Guides on selecting the required cut-off option for calibration.
Details how to set the calibration length and adjust cut-offs using the 'N' value.
Guides on resetting the pick-up gauge indicator using a flat surface.
Explains how to enter a licence code to change unit configuration.