Character of individual components:
Component KOH (pure) Pb (pure)
Melting point/range
360°C 328°C
Boiling point/range
1320°C 1744°C
Specific gravity 2.04 11.34
pH N/A N/A
Solubility in water Infinite Insoluble
Appearance and odor Odorless white or yellowish
crystals
odorless gray metal
Fire and explosion hazard data
Flash point: N/A Flammable limit N/A LEL: N/A UEL N/A
Extinguishing media: No special agents recommended.
Special fire fighting equipment: Wear NIOSH/OSHA approved self-contained breathing apparatus
and protective clothing to prevent contact with skin and eyes.
Unusual fire and explosion hazards: Emits toxic fumes under fire conditions.
Reactivity data
Stability: Stable
Incompatibilities: Aluminum, organic materials, acid chlorides, acid anhydrides,
magnesium, copper. Avoid contact with acids and hydrogen
peroxide > 52%
Hazardous decomposition byproducts: Toxic fumes
Hazardous polymerization: Will not occur
Emergency and first aid procedures
Eye contact: Flush eyes with water for at least 15 minutes and get immediate
medical attention.
Skin contact: Wash affected area with plenty of water and remove
contaminated clothing.
Ingestion: Give large amounts of cold water. Do not induce vomiting. Seek
medical attention. Do not administer liquids to an unconscious
person.
Inhalation: Liquid inhalation is unlikely. If it occurs, remove to fresh air and
seek immediate medical attention.