3.5.3 Hand start
Set the engine speed control lever to full load.
Machines with emergency-stop-connection :
Press emergency-stop-connection.
Machines with electrical start :
Turn ignition key via position I.
Move the decompressor (1) lever until it stops in start position.
Insert the starting crank (2) and turn it with increasing speed.
After starting of the engine,
release ignition key.
Set the speed lever to idle.
Allow the engine to run for 2-3 minutes in order to warm up.
By misfire ignition return the decompressor lever to its initial
position and repeat steps 1-5.
3.5.4 Switching-off the engine
Allow the engine to run a short while on idling.
Set the speed lever to stop.
Additionally by electrostart:
Turn the ignition key to «0» position. (The indicator lamps
should go out.)
Remove the key.
3. Operation
36
Attention
Machines with electrical starter: Never hand start
with a disconnected battery, this leads to immedi
-
ate destruction of the regulator.
1
B8299005.cdr
2
B8299006.cdr
Attention
Do not switch-off the engine by full load and don’ t
use the decompressor lever.
Danger
At the end of a working day or a break protect the
key from unauthorised access.
Important
The horn will sound if the ignition key is not returned to
the «0» position; a risk of total battery discharge ex-
ists.