WARNING
Do not use any means to speed up the defrosting
process or to clean, other than those recommended
by the manufacturer.
The appliance must be placed in an area without a
continuous source of ignition (for example: open
flames, gas or electrical appliances in operation).
Do not pierce and do not burn.
Be aware that refrigerant gases can be odorless.
The device must be installed, used and stored in an
area of more than 15m².
This appliance contains 290g of R290 refrigerant
gas.
R290 is a refrigerant gas compliant with European
environmental directives. Do not drill any part of the
refrigerant circuit.
If the appliance is installed, used or stored in an
unventilated place, the room must be designed in
such a way as to prevent the accumulation of
refrigerant leaks resulting in a risk of fire or
explosion due to the ignition of the refrigerant
caused. by electric heaters, stoves, or other sources
of ignition.
The device must be stored in such a way as to
avoid mechanical failure.
People who operate or work on the refrigerant
circuit must have the appropriate certification issued
by an accredited body that guarantees competence
in handling refrigerants according to a specific
assessment recognized by industry associations.