EN-24
MAINTENANCE AFTER USE:
If you do not plan to use the device for an extended period:
1. Remove the rubber plug from the drain opening (bottom of the unit) to drain the unit.
2. During ½ day and in good weather, operate the appliance in VENTILATION mode only so that
it dries inside and prevents it from molding.
3. Switch off and unplug the appliance.
4. Clean the air filter and reinstall it.
5. Remove the air hoses and store them carefully. Close the hole tightly.
6. Always unplug the machine from the power outlet before putting it away.
TECHNICAL SPECIFICATIONS :
BRAND
AMSTA
REFERENCE
AMCLI180E
ENERGY EFFICIENCY CLASS
A
NOMINAL COOLING CAPACITY (kW)
P
rated
refrigeration
5.2
NOMINAL ABSORBED COOLING CAPACITY (kW),
P
EER
2.1
NOMINAL ENERGY EFFICIENCY COEFFICIENT,
EER
rated
2.6
ENERGY CONSUMPTION (kWh / 60min),
Q
SD
2.1
The energy consumption of 2.1 kWh for 60 minutes, based on results obtained under standardized
test conditions. The actual energy consumption will depend on the conditions of use and the location
of the device.
ACOUSTIC POWER LEVEL (dB)
IN "COOLING" MODE
L
WA
65
REFRIGERANT
R290 (0.3 kg)
Model :
AMCLI180E
Supply voltage :
Power consumption :
230V ~50 Hz
2026W
Cooling capacity :
5270W
Refrigerant gas:
R290 / 300g
Type of fuse used:
T3.15A, AC250V
Discharge pressure:
1.8 MPa
Suction pressure:
0.6 MPa
Maximum tolerated
pressure
3.0 MPa
Protection class:
Class I