Brand | Analytik Jena |
---|---|
Model | SPEKOL 1300 |
Category | Measuring Instruments |
Language | English |
Identifies warning and safety labels placed on the SPEKOL 1300 instrument.
Explains symbols and navigation system used within the user manual.
Specifies authorized applications for the SPEKOL 1300 and consequences of misuse.
Emphasizes adherence to local safety rules relevant to device operation.
Outlines qualifications needed for operating the SPEKOL 1300.
Details how to safely stop the device in an emergency.
Covers risks associated with electrical voltage and proper grounding.
Warns against operating the device in rooms with potential explosion hazards.
Advises against direct or indirect viewing of UV lamp radiation to prevent eye injury.
Cautionary note on handling lamps to avoid contamination and maintain performance.
Warns about overheating due to covered ventilation slots and advises removing dust covers.
Advises caution to prevent liquids from entering the device to avoid damage.
Warns against exposure to aggressive vapors and corrosive substances.
Identifies components on the front panel of the SPEKOL 1300, including display and cell selector.
Details the RS 232 interface and analog output ports on the right side of the instrument.
Identifies rear panel elements like power socket, fuse holder, and voltage selection.
Specifies environmental and space requirements for installing and transporting the SPEKOL 1300.
Guides through the initial steps of unpacking, checking, and setting up the instrument.
Provides instructions for cleaning the SPEKOL 1300 device and sample compartment.
Details the procedure for safely replacing defective line fuses in the instrument.
Step-by-step guide for safely replacing the halogen lamp.
Step-by-step guide for safely replacing the deuterium lamp.
Describes the manual 4-position cell changer for 1 cm, 5 cm, and 10 cm cells.
Details an adjustable cell holder for micro and ultra micro cells requiring precise alignment.
Describes a holder for round test kit cells up to 16 mm diameter.
An attachment for thermostatted cell holders, adaptable to SPEKOL 1500.
Instructions for connecting and using the flow-through unit with an adjustable cell holder.
Accessory for temperature-dependent measurements, connectable to an external thermostat.
Describes a 3-cell water-jacketed changer for 10mm pathlength cells.
Instructions for installing a printer via RS 232 and power connection.
Describes the digital readout for transmittance, absorbance, and concentration.
Explains the purpose and operation of various buttons like MODE, FUNC, ENT, etc.
Lists various methods accessible via the [FUNC] button, like language selection and lamp exchange.
Procedure for changing the instrument's display language between English and German.
Instructions on how to switch the UV and VIS lamps on or off.
Guides on performing measurements in Absorbance or Transmittance modes.
Details methods for determining sample concentration via calibration.
Explains the method for bio-analytical determination of DNA, RNA, and Proteins.
Procedure for performing time-dependent kinetic measurements.