Save Amp Value(s)
This test is only for systems equipped with an ANILAM AC Amplifier (P/N
33001279).
Saves all modified amplifier parameters to non-volatile memory. This
must be done after performing a signal gain test and/or a balance test.
Balance Test – When 8dhBalance test [Balance (F6)] is selected and if
the Communication link between the CNC and ANILAM AC Drive is
enabled/open, the Parameter IAO (Analog 1 Input Offset) will be
displayed and you will be able to modify it by using the up/down arrow
keys. Use right/left arrow to change the increment amount (which is set
on Setup Utility). Save the final value by selecting Save Amp Value(s)
[MISC (F9)].
Signal Gain Test – When Signal Gain test [SigGain (F7)] is selected and
if the Communication link between the CNC and ANILAM AC Drive is
enabled/open, the Parameter IAS (100% PWM RPM Value) will be
displayed and you will be able to modify it using the up/down arrow keys.
Also, the Compensation (equivalent to Comp Pot) parameter GVC
(Velocity Loop Master Gain) will also be displayed, you will be able to
modify it by using right/left arrow keys. Every time you press the arrow
keys, the value will be incremented by the amount entered in the Setup
Utility. Save the final value(s) by selecting Save Amp Value(s) [MISC
(F9)].
These two tests should cover the equivalent of Signal, Balance & Comp
Pots on the analog drives.
Amp Test Link
This test is only for systems equipped with an ANILAM AC Amplifier (P/N
33001279).
This enables/disables the communications monitor. The communications
monitor has two modes of operation: Monitor and Command. Use hot
key (
CTRL + F7) to switch between the two modes..
Monitor: (Default) During this mode, you can monitor all
communication between the Amplifier and the Control.
Command: During this mode, it not only monitors all communications;
but also, allows you to send direct commands to the
Amplifier.
Reset Amplifier
This test is only for systems equipped with an ANILAM AC Amplifier (P/N
33001279).
This resets the Amplifier (ANILAM AC Drive).