8
Specifications Rx
Item Specification Remarks
Decoder
Number of Inputs 2 (Data, xData)
1 (External clock)
K Connector (female)
Baud Rate 10 to 32.1 Gbaud (DFF ON mode)
10 to 28.1 Gbaud (DFF OFF mode)
Uses MU19040A with external clock
Uses CDR of MU195040A-022
Data Input Amplitude 0.4 Vp-p (typ.)
0.5 Vp-p (max.)
Single-ended
Data Input Sensitivity 40 mV (typ.) 28 Gbaud, Per Eye, Eye Height, Single-
ended at E-6
Clock Input Frequency 10 to 32.1 GHz (DFF ON mode) Full-rate clock
Clock Input Amplitude 0.3 to 1.0 Vp-p External Clock Input
Number of Outputs 3 (Data1, Data2, Monitor Data) K Connector (female)
Data Output level 0/–0.3 V (typ.)
Internal DFF Selectable ON/OFF Uses external Clock for D-FF ON mode
CTLE
Number of Inputs 2 (Data, xData) K Connector (female)
Input Amplitude 0.4 V (max.)
CTLE Gain –12 to 0 dB adjustable
CTLE Peak Frequency 14 GHz (typ.)
Number of Outputs 2 (Data, xData) K Connector (female)
G0376A 32Gbaud PAM4 Decoder with CTLE + MU195040A 21G/32G bit/s SI ED