EasyManuals Logo

Anton Sprint eVo3 User Manual

Default Icon
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
21
Sprint eVo
1
/eVo
2
/eVo
3
Specification
V. Specification
Instrument
Operating temperature
range
-10°C to 50°C (14°F to 122°F)
Battery Lithium-Ion. Life up to 9 hours dependant on test
used.
15% left warning.
Recharge time Minimum 6 hours from flat.
Charger input voltage 230V;50HzAC
Standard Fuels Natural gas, LPG, heavy oil, light oil, coal, wood,
wood pellet dry, coke, Biomass and Bagasse
Display Blue back lit graphic LCD
Menu Intuitive structure, tab selection on screen
Dimensions 92 x 176 x 59 (mm)
Function buttons/key pad 5 button keypad
Weight 528 g
Operating time: 9 hours (6 hours continuous pump)
Pump Flow fail indication, SmartPurge
Enclosure Integrated robust protective case.
Protective rubber boot with integral magnets
Standards BS7927, EN50379, BS7967
Data Logging Reports Up to 200 reports, depending on type
Probes
Standard Efficiency Flue Probe
Insertion length 250 mm (9.9”) with adjustable depth gauge
Maximum temperature 800°C (1472°F)
Construction Ergonomic pistol grip with stainless steel shaft,
in-built with thermocouple, in-line water trap/filter
K-type thermocouple Accuracy ±1°C or ±0.3% of reading, whichever
is best
Protective shaft for thermocouple
Hose length 2000 mm
Gas Escape Sensor Probe
Gas Escape Sensor: 0-10,000ppm natural gas

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Anton Sprint eVo3 and is the answer not in the manual?

Anton Sprint eVo3 Specifications

General IconGeneral
BrandAnton
ModelSprint eVo3
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals