EasyManua.ls Logo

Anton Sprint Pro User Manual

Anton Sprint Pro
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User Manual
M07723
October 2018
Issue 1
Multi-function Flue Gas Analyser
T: +44 (0)870 428 0075
www.anton-group.com
Sprint Pro 3
5430910000J18
Your company name
Your Company Phone
Question and Answer IconNeed help?

Do you have a question about the Anton Sprint Pro and is the answer not in the manual?

Anton Sprint Pro Specifications

General IconGeneral
BrandAnton
ModelSprint Pro
CategoryMeasuring Instruments
LanguageEnglish

Summary

Sprint Pro Unpacking

Unpacking the Sprint Pro

Instructions for unpacking the Sprint Pro and its accessories from the packaging.

Sprint Pro Orientation: Device Overview

Component Identification

Details the main components and connections of the Sprint Pro analyser.

Keypad and Display Functions

Explains the operation of soft keys, ESC, and ON/OFF/ENTER buttons.

Sprint Pro Orientation: Operation Basics

Probe Connections

Guides on connecting probes for different test types like flue gas and differential temperature.

Powering On and Menu Navigation

Procedure for powering on the Sprint Pro and navigating its main menu.

Switching Off the Sprint Pro

Steps to properly power down the Sprint Pro analyser.

Sprint Pro Battery Management

Battery Charging and Indicators

Instructions for charging the battery and understanding power indicators.

Sprint Pro Pump and Menu Structure

Pump Operation Details

Details the function of the internal pump during purging and tests.

Keypad and Menu Navigation

Description of the colour LCD display, soft keys, and menu structure.

Sprint Pro Menu Structure Diagram

Menu Navigation Flow

Illustrates the hierarchical structure of the Sprint Pro menus.

Set Up & Menu Configuration Options

Fuel Options Configuration

How to select and set the fuel type for analysis.

Units of Measurement Settings

Configuring units for pressure, temperature, and efficiency.

Analyser Settings and Report Options

Analyser Settings Management

Adjusting display, auto-off, backlight, and key click settings.

Report Export and Mobile App Settings

Selecting methods for exporting logs and reports to printers or mobile devices.

Supervisor Settings and CO2 Zeroing

Supervisor Settings and Passwords

Setting date/time, editing report headers, and managing passwords.

CO2 Zeroing Procedures

Steps for zeroing the CO2 sensor in clean air or with a scrubber.

Performing Tests

Important Test Preparations and Zeroing

Key steps before performing tests, including probe connection and zeroing.

Flue Gas Analysis

Guide to conducting flue gas analysis and viewing results on the device.

Pressure Tests: Let-by, Stabilisation, Tightness

Procedures for performing pressure-related tests on the Sprint Pro.

Advanced Pressure and Temperature Tests

Advanced Pressure and Temperature Tests

Performing differential, working, and operating pressure/temperature tests.

Room Safety and Appliance Tests

Room Safety and Appliance Tests

Guides for conducting room safety and appliance sweep tests.

Gas Escape and Ambient Air Monitoring

Gas Escape and Ambient Air Monitoring

Procedures for gas escape detection and ambient air monitoring.

Logging and Reporting

Logging Test Results

Procedure for logging test results and managing stored logs.

Retrieving and Deleting Logs

How to access, view, and remove logged test data.

Exporting Reports

Exporting Reports via IR Printer

Steps to print logs and reports using an IR printer.

Exporting Reports via Mobile App

Transferring data to a mobile app via Bluetooth or Wi-Fi.

Maintenance and Calibration

General Unit Cleaning and Care

Guidelines for cleaning the Sprint Pro display and buttons.

Unit Calibration Requirements

Information on annual calibration and overdue warnings.

Sprint Pro Filter and Water Trap Maintenance

Drying Water Trap and Filters

Procedure for drying water trap and filters after use.

Filter Cleaning and Replacement

Instructions for cleaning or replacing dust and water filters.

Sprint Pro Specifications

Operating and Performance Specifications

Details on operating temperature, battery, standards, and fuel options.

Flue Probe Specifications

Details on the flue probe's insertion length and construction.

Measurement Specifications

Measurement Specifications: Gas Analysis

Specifications for gas measurements including range, resolution, and accuracy.

Measurement Specifications: Room Safety & Ambient

Specifications for CO/CO2 measurements in room safety and ambient monitoring.

Charger and Interface Specifications

Pressure and Temperature Specifications

Details on pressure and temperature measurement ranges and units.

Charger and Interface Specifications

Details on charger requirements and device interfaces.

Sprint Pro Accessories and Spare Parts

Flue Probes and Related Accessories

List of available flue probes and associated accessories.

Gas Escape Probe and Accessories

List of gas escape probes and associated accessories.

Troubleshooting

Troubleshooting: Power, Blockage, Printer, Zeroing

Solutions for common issues like power, blockages, printer errors, and zeroing failures.

Troubleshooting: CO Alarm and Sensor Issues

Understanding and responding to CO alarms and sensor-related problems.

Troubleshooting: Sensor and Calibration Issues

Troubleshooting: Sensor and Calibration Issues

Addressing unstable readings, sensor errors, and date/calibration problems.

Appendix I: Room Safety Test

Room Safety Test Overview and Criteria

Introduction to BS 7967 CO testing and pass/fail specifications.

Room Safety Test Results Interpretation

Room Safety Test Result Codes and Prompts

Explanation of result codes and on-screen prompts for safety tests.

Room Safety Test Pass Cases for CO Levels

Criteria for a passing room safety test, including normal and low CO levels.

Room Safety Test Failure Analysis

Room Safety Test Failure Analysis: CO Levels

Analysis of failure codes like FAILED (1), (2), (3), (4) in safety tests.

Room Safety Test: Multiple Peaks and Unstable CO

Interpreting multiple peaks or unstable CO readings during safety tests.

Room Safety Test: CO Level Exceeds Limits

Room Safety Test: CO Level Exceeds Limits

Understanding failures related to CO levels exceeding limits near test end.

Warranty Information

Sprint Pro Manufacturer's Warranty

Details the 5-year warranty and its exclusions for the Sprint Pro.

Warranty Limitations

Warranty Invalidation Conditions

Circumstances that can invalidate the Sprint Pro warranty.

Expected Lifespan of Components

Estimated lifespan for the battery and various sensors.