Do you have a question about the APC Symmetra LX and is the answer not in the manual?
| Form factor | 1U |
|---|---|
| Certification | CSA, UL 1778 |
| Product color | Silver |
| Battery voltage | 120 V |
| Battery capacity | 864000 mAh |
| Battery technology | Sealed Lead Acid (VRLA) |
| Dimensions (WxDxH) | 210 x 546 x 140 mm |
| Battery life | 3 year(s) |
| Operating altitude | 0 - 3000 m |
| Storage temperature (T-T) | -15 - 45 °C |
| Operating temperature (T-T) | 0 - 40 °C |
| Storage relative humidity (H-H) | 0 - 95 % |
| Harmonized System (HS) code | 85079080 |
| Weight | 29100 g |
|---|---|
| Package weight | 32280 g |
Provides an introduction to the Symmetra LX operations guide.
Describes the alphanumeric display, navigation keys, status indicators, and audible alarm.
Details the meaning of status indicators (LOAD ON, ON BATT, BYPASS, FAULT) and navigation key functions.
Explains how to navigate the PowerView monitoring screen and Main Menu.
Overview of fundamental commands for operating the UPS.
Procedure for supplying AC utility power to the UPS unit and its connected equipment.
Guide to configuring the correct output voltage for the UPS application.
Steps to turn on the UPS output and supply power to the connected load.
Procedure for safely turning off the UPS output power and load equipment.
Explains manual and automatic bypass operations and requirements.
Steps to bypass UPS electronics and directly supply power using PowerView commands.
Manual bypass using the maintenance bypass switch and input circuit breaker.
Instructions for downloading new firmware to change the PowerView language.
Continues steps for downloading language files via HyperTerminal and updating the PowerView.
Describes commands organized by menu hierarchy in the PowerView.
Allows monitoring of installed APC accessories via the PowerView.
Use to control power flows to and from the UPS, including output on/off and self-tests.
Allows user customization of PowerView display settings like Date/Time, Password, and Beeper.
Provides useful information for troubleshooting system faults and module status.
How to access context-sensitive help screens on the PowerView.
Allows customization of the UPS log, viewing events, and statistics.
Details on listing event groups, clearing logs, and specific event types.
Displays load, battery, power module, voltage, and current information.
Customizes UPS functionality including shutdown parameters, delays, and defaults.
Includes settings for alarms, redundancy, load limits, runtime, bypass, and UPS ID.
Lists PowerView messages, reasons, and corrective actions for system conditions.
Addresses issues like module changes, battery capacity, and input frequency during startup.
Covers AC adequacy for bypass, low/no AC input, and module/battery status changes.
Deals with battery/module additions/removals, intelligence module status, and redundancy.
Identifies issues with bad battery modules, power modules, and intelligence modules.
Addresses load exceeding alarm thresholds and loss of redundancy.
Covers redundancy below threshold and predicted runtime below threshold.
Diagnoses bypass unavailability, contactor issues, internal faults, and overload bypass.
Covers on-battery status, battery replacement needs, UPS faults, and overload shutdowns.
Addresses input breaker trips, fan failures, intelligence module control, and inter-module communication.
Steps to follow if the UPS requires service, including contacting support and packaging.
Information on how to contact APC for support and visit their website.
Guidance on battery replacement kits and proper battery recycling procedures.