Time:Clock setting is performed in the same manner; from the
initial submenu select the Time: eld with the rotary control and
then press Enter to select the hour.
LCD submenu
This single parameter in this menu lets you adjust the LCD
screen brightness to suit your working environment. The
scaling is as a percentage of the maximum brightness, and the
default value is 100%.
Clock submenu
The Intelli-X
2
maintains an event log which may be viewed on
the front panel LCD or by using Intelli-Ware; the Clock submenu
allows the internal clock/calendar to be set correctly so that the
log details are accurate.
Date: This eld is selected by default; to change the date,
press Enter to highlight the day only, then either press Enter
again to modify the day with the rotary control, or use the rotary
control to select either the month or the year. These can then
be altered in the same manner.
Security Menu
It may be advisable to “lock” certain features of the Intelli-X
2
,
to prevent inadvertent system changes from being made at a
critical time. The Security menu offers three options, the default
state being that all restrictions are ‘off’, and thus all the relevant
changes can be made if wished.
A tick in the checkbox means that the operating function is
enabled. Press Enter to remove/replace the tick. The three
options are:
Allow mute when unticked, the front panel MUTE buttons
become inoperative. This applies to both the Input channels and
Output channels. Note that it is the MUTE buttons themselves
that are disabled active channels cannot be inadvertently
muted, and channels already muted cannot become unmuted.
Allow preset recall when unticked, it is not possible to load
a different Preset .
Allow remote controlwhen unticked, no commands sent via
Ethernet ports (i.e. from Intelli-Ware) will be executed. In large
theatre systems, for example, this is a useful function once the
unit has been set up ready for a show, as it ensures that no
computer activity on the network can affect the unit.
Security menu softkeys – Locking and PIN change
From the Security menu, the following softkey functions are
available:
Change PIN code. This allows the PIN needed
for the Unlock function to be changed from the factory default
code. Pressing Change pin code opens the Modifying the pin
code dialogue box:
Scroll to the Old Pin Code eld, and enter the current PIN using
the same method as for entering the PIN code to unlock. (You
cannot change the PIN without knowing the current one). Then
scroll to the New Pin Code eld and enter the new code. Press
Apply to make the change or BACK/HOME to Cancel.
Lock/Unlock function. This is the same Lock function
that is available from the main menu top page. Selecting Lock
prohibits access to the Audio, Settings or Security menus.
Because the Security menu is no longer accessible once Lock
is applied, unlocking must be selected from the main menu top
page.