(5) DCA : Auto-ranging
Range Resolution Accuracy Over voltage protection
0 ~ 40.0A 0.1A
600A rms
40.0A ~ 400.0A 0.1A
400A ~ 600A 1A
±(1.9% reading + 10 digits)
±(1.5% reading + 10 digits)
±(1.5% reading + 7 digits) *
1. * For 200.0A ~ 400.0A add 1% to accuracy.
2. Temperature Coefficient : 0.2 x (Spec.Acc'y) / < 21 or > 26.
3. Operating Temperature : 0 to 30 ( 80%RH) , 30 to 40 ( 75%RH)