13
(6) ACA : Auto-ranging
Range Resolution Accuracy
Frequency
Response
Overload
Protection
0 ~ 40.0A 0.1A
±(1.9% reading + 7 digits)
50Hz ~ 60Hz
600A r.m.s.
40.0A ~ 400.0A 0.1A
±(1.9% reading + 5 digits) **
400A ~ 600A 1A
±(1.9% reading + 10 digits)
0 ~ 40.0A 0.1A
±(2.5% reading + 7 digits)
61Hz ~ 400Hz
40A ~ 400.0A
0.1A
±(2.5% reading + 5 digits) *
400A ~ 600A 1A
±(2.5% reading + 10 digits)
1. * For 200.0A ~ 400.0A add 1.1% to accuracy.
2. ** 200.0A ~ 400.0A add 1.6% to accuracy for 36RⅡ.
200.0A ~ 400.0A add 1.1% to accuracy for 36Ⅱ.