7
(3) Diode testing
Range Resolution Accuracy Max. test current
Max.open cuicuit
voltage
1.5mA 3.2V
1mV ±(1.5%rdg + 5dgt)
Overload protection: 500V DC/AC max.
(4) LED Test
Testing Voltage : 3.2V max.
Test Current : 2mA or 10mA two ranges.
LED lamp lighted test, display reading is LED forward voltage approx.