CSPP Capacitor Charging Unit Operation Manual
CSP-CSPP-8000/2
_________________________________________________________________________________________________________
__________________________________________________________________________________________________________
Page 33 of 59
4. Repair And Fault Finding on CSP Power Supplies
It is not recommended that any internal repairs are undertaken to any CSPP by anyone other than
a suitably qualified engineer. AAE can take no responsibility for loss or injury caused by repairs
that have not been performed either within our own Laboratories or by our own registered service
agents.
During diagnosis procedures it is recommended that the power selection switch is placed at 50J
and a suitable Transducer or Dummy Load is attached to the output.
SAFETY NOTICE
It is also imperative that the HV Charger main supply is
disconnected when any adjustments are made within
the unit.
Even with the supply disconnected lethal voltages may
be present, so use extreme caution when making any
adjustments or measurements.
Make sure that a responsible assistant is present to
prevent people from walking into the service area. They
should also be capable of taking the correct actions in
the event of an emergency.
Try to keep one hand in your pocket at all times and
wear non-conductive footwear.
IF IN DOUBT / DONT