LOCATING THE AIR CLEANER
CLEARANCE
It is important to leave enough room to
remove and re-install the inner housing
for lter replacement (see FIGURE 3).
18”
12”
29”
SERVICE
CLEARANCE
90-1347
FIGURE 3: CLEARANCE FOR INNER
HOUSING REMOVAL
INSTALLATION OPTIONS
The Model 5000 can be installed in a
variety of ways. FIGURES 4-7 show some
of the possibilities.
The air cleaner may be installed on the
left or right side of the air handler. If
installed on the right, the ON/OFF switch
will be on top and the nameplate will be
on the bottom. Remove the nameplate
and rotate it 180° to read properly.
APPLICATIONS WITH A
HUMIDIFIER
An Aprilaire Whole-House Humidier
can be mounted upstream from the air
cleaner.
NOTICE
Do not install an atomizing
humidier upstream of the air
cleaner. Water or mist will cause the
power supply to shut down.
AIRFLOW
NOTE:
AIR CLEANER
OUTER HOUSING
CAN SUPPORT
UP TO 400 LBS.
90-1158A
90-1161A
FIGURE 4: BOTTOM RETURN IN
UPFLOW “HIGHBOY” INSTALLATION
FIGURE 6: SIDE RETURN IN UPFLOW “HIGHBOY” INSTALLATION
EITHER OF THE METHODS SHOWN WILL RESULT IN A NARROWER “FOOTPRINT”,
CREATING BETTER CLEARANCE IN TIGHT MOUNTING APPLICATIONS.
FIGURE 7: COMPACT SIDE RETURN IN UPFLOW “HIGHBOY” INSTALLATION
AIRFLOW
LEFT SIDE INSTALL SHOWN
90-1159A
FIGURE 5: INLINE IN DUCT, HORIZONTAL
OR VERTICAL INSTALLATION
AIRFLOW
LEFT SIDE INSTALL SHOWN
AIRFLOW
30° MAX.
45° MAX.
MINIMIZE
ANGLES
WHERE
POSSIBLE
AIRFLOW
PLENUM
BOX
AIRFLOW
PLENUM
BOX
SIZE PLENUM
BOX TO FIT
OUTER HOUSING
WITHOUT DOOR:
17-3/4
x 28-1/8”.
SEE
FIGURE 1
FOR COMPLETE
DIMENSIONS.
90-1160A
90-1163A90-1162A