SAFETY INSTRUCTIONS
Read this entire installation manual before beginning installation of the Aprilaire 6000 Series Zone Control System. For questions call Aprilaire
customer support at (800) 334-6011 or visit AprilairePartners.com.
WARNING
1. 120 volts may cause serious injury from electrical shock. Leave power disconnected until installation is complete.
2. The system is designed for indoor use only. Do not expose any of the components to moisture.
WARNING
1. Turn o the system power before removing or installing any wires into the terminals of any component of the system. Wiring with a live
circuit can lead to electrical shorts that can damage components.
2. Installation must be done in accordance with all applicable codes.
3. Installer should touch a grounded metal object before handling the components of the system. This will prevent any static discharge that
may cause damage.
4. A 6000 Series Zone Control System may not control temperature properly unless the heating and cooling system is properly sized and
balanced.
5. Insucient air flow or excessive temperatures through the heating and cooling system could result in equipment damage. Refer to the
manufacturer’s recommendations for minimum safe airflow and temperature requirements.
6. Do not mount the 6000 Series Control or Sensors on any exterior wall or equipment supply ductwork.
7. Do not install the system components where temperatures exceed 158°F (70°C) or are below 32°F (0°C), non-condensing.
8. Improper system installation could cause water damage from frozen pipes. Check system operation after installation.
READ AND SAVE THESE INSTRUCTIONS
6000 Series Zone Control System
For models 6010, 6015, 6020, 6025, 6030, 6035,
6040, 6045, 6045M
Safety & Installation Instructions
1
Question and Answer IconNeed help?

Do you have a question about the Aprilaire 6045 and is the answer not in the manual?

Aprilaire 6045 Specifications

General IconGeneral
BrandAprilaire
Model6045
CategoryControl Systems
LanguageEnglish

Summary

Safety Instructions

General Safety Precautions

Key safety warnings including electrical shock and indoor use only.

Specifications

Layout

6000 Series Control Home Screen

6000 Series Hub Installation

Hub Location and Mounting

Guidelines for selecting an appropriate location and mounting the 6000 Series Hub.

6000 Series Hub Wiring

Transformer Connections

Instructions for connecting the transformer to the 6000 Series Hub.

6000 Series Control and Sensor Installation

Location Recommendations

Guidance on where to mount the 6000 Series Control and Sensors.

Wiring Connections

Installer Setup

Installer Setup Menu Navigation

How to access and navigate the installer setup menu.

Installer Tools and Test Functions

Overview of installer tools like import/export settings and system testing.

Indoor Air Quality (IAQ) Settings

Wi-Fi Setup and Connectivity

6000 Series Sensor Operations

Installer Test Procedures

How to perform equipment checkout tests using the control or hub.

Sequence of Operation

Multistage Equipment Staging

Troubleshooting Common Issues

Display Blank or No Power

Steps to resolve a blank display or no power issue on the Hub.

Heating System Not Responding

Troubleshooting for when the heating system doesn't activate.

Cooling System Not Responding

Troubleshooting for when the cooling system doesn't activate.