INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Register Your Humidier ........................................2
PRINCIPLE OF OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
OPERATING INSTRUCTIONS - MODEL 720A . . . . . . . . . . . . . . . . . . . . . . . . 3
Automatic Digital Humidier Control Indicator Lights.........3
Blower Activation................................................3
Automatic Mode ................................................3
Manual Mode....................................................4
Change Water Panel Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Test/Reset........................................................4
OPERATING INSTRUCTIONS - MODEL 720M. . . . . . . . . . . . . . . . . . . . . . . . 4
Check the Humidier Operation - Manual
Humidier Control...............................................5
TROUBLESHOOTING GUIDE .........................................5
EFFECT OF WATER CHARACTERISTICS .............................6
FAN SPEED ..........................................................6
ANNUAL MAINTENANCE ............................................6
Annual Summer Shutdown .....................................6
Maintenance Instructions.......................................6
LIMITED WARRANTY ................................................8
REGISTER YOUR HUMIDIFIER
Register your product at aprilaire.com/warranty
or by using the QR code, to receive important
updates and notications, and to streamline
the process in the unlikely event you le a claim.
Purchase only a genuine HydroCore to maintain
peak performance. For more information, visit our
website at aprilaire.com.
TABLE OF CONTENTS
WARNING
ELECTRIC SHOCK HAZARD: 120 volts may cause serious
injury from electric shock. Disconnect electrical power
and water before servicing. Leave power and water
disconnected until service is completed.
RISK OF SCALDING. Water temperature over 125°F (52°C)
can cause severe burns and scald instantly. Shut off the
hot water supply before disconnecting or tapping into
any hot water supply line.
CAUTION
SUDDEN OPERATION MAY CAUSE PERSONAL INJURY OR
PROPERTY DAMAGE. Turn the humidier control to OFF or
lowest setting before servicing.
Shut off HVAC system and humidier before removing
cover. Loose particulate may irritate eyes.
INTRODUCTION
When humidity is properly controlled within a home, it
provides effective virus protection. Air that’s too dry can lead
to conditions that allow airborne viruses to thrive. By adding
humidity to dry air, the amount of time a virus can survive in
the air drops drastically. By maintaining balanced humidity
between 40% and 60% RH (relative humidity) year round, you
can reduce the airborne incidence of health concerns like
bacteria, viruses, and dust mites.
While 40% to 60% is ideal, this is hard to achieve in some
climates during cold months without potential condensation
damage to the home. Your AprilAire Humidier can help
maintain up to 45% RH, with a recommended range of 35% to
45% RH. As the temperature drops, the lower range may be
all a home can manage depending on various conditions
such as age of windows, air exchanges, insulation type, etc.
As temperatures warm, higher levels can be maintained. See
TAB LE 1 and TABLE 2 for guidelines.
Your humidier will require annual maintenance to assure
continued peak performance. Continue reading to learn more
about benets, maintenance, and operation of your humidier.
Register Your
Humidier
SERIAL NUMBER LOCATION
2 English